![Moduline systems DMC-B Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/moduline-systems/dmc-b/dmc-b_operation-manual_1818388010.webp)
Reliable liquid dispensing
at an affordable price
8
SYRINGE REPLACEMENT
To replace the syringe, empty all fluid from the syringe, remove inlet lines from
fluid reservoir, then follow the steps below:
1. To replace the syringe, turn the power on and initiate the prime cycle. When the
syringe activator arm is at the bottom of its stroke, turn the power off.
2. Turn the plunger lock screw counterclockwise 3 turns.
3. Turn the syringe counterclockwise and remove from the valve.
To install the syringe follow the steps below:
4. Screw the threaded portion of the syringe clockwise into the valve.
5. Fully seat the plunger into the syringe activator arm.
6.
Securely tighten (clockwise) the plunger lock screw.
Syringe
Plunger
Lock Screw
Syringe
Plunger Holder
Valve
4
5
6