4.
Understanding the main box features
12V Battery Bank:
•
The use of an AGM battery is highly recommended for any Modul-System power application.
•
For battery sizing, you need to identify what you wish to operate, and for how long. It is
recommended that you purchase as much battery capacity as possible.
DC Fuse or Circuit Breaker:
•
DC-rated fuse or DC-rated circuit breaker connected along the DC positive line is required. The
size of the input fuse must be compatible and calculated with the load required from the box and
to protect the DC cable input run.
M-S part number
MEGA input fuse ampage description
Colour
C-MEGA40-5
Mega fuse 40A black, 5 pcs
Black
C-MEGA60-5
Mega fuse 60A black, 5 pcs
Black
C-MEGA100-5
Mega fuse 100A yellow, 5 pcs
Yellow
C-MEGA125-5
Mega fuse 125A green, 5 pcs
Green
C-MEGA150-5
Mega fuse 150A orange, 5 pcs
Orange
C-MEGA175-5
Mega fuse 175A white, 5 pcs
White
C-MEGA200-5
Mega fuse 200A blue, 5 pcs
Blue
C-MEGA225-5
Mega fuse 225A brown, 5 pcs
Brown
C-MEGA250-5
Mega fuse 250A pink, 5 pcs
Pink
C-MEGA300-5
Mega fuse 300A grey, 5 pcs
Grey
C-MEGA350-5
Mega fuse 350A dark green, 5 pcs
Dark green
C-MEGA400-5
Mega fuse 400A purple, 5 pcs
Purple
C-MEGA1A-50
Mega fuse holder
CAUTION:
Always disconnect the DC power between the box and the battery bank during service,
maintenance or troubleshooting.