The following settings are possible:
Switch:
Position OFF:
Position ON:
1.1
ON
1 2 3 4 5 6 7 8
1
ON
1 2 3 4 5 6 7 8
2
Movement runs on time (if
synchronized)
Movement runs to 12:00 posi-
tion
1.2
ON
1 2 3 4 5 6 7 8
1
ON
1 2 3 4 5 6 7 8
2
Second hand in stepwise
(wobbling) mode
Second hand in continuous
mode
1.3
ON
1 2 3 4 5 6 7 8
1
ON
1 2 3 4 5 6 7 8
2
Second hand with stop at
12:00 (rotation time ap-
proximately 58 s)
Second hand without stop at
12:00
1.4
ON
1 2 3 4 5 6 7 8
1
ON
1 2 3 4 5 6 7 8
2
Time zone from
internal
time zone table
(selection 0..63 with
switches 2.1 to 2.6)
Time zone table provided by
time zone server
(selection of entry 1..15 with
switches 2.1 to 2.4)
1.5 to
1.8
ON
1 2 3 4 5 6 7 8
1
ON
1 2 3 4 5 6 7 8
2
Unicast mode:
1.5: 0
1.6: 0
1.7: 0
1.8: 0
Multicast group address
or
slave address (binary value):
1.5: 1
1.6: 2
1.7: 4
1.8: 8
2.1 to
2.6
ON
1 2 3 4 5 6 7 8
1
ON
1 2 3 4 5 6 7 8
2
Time zone (binary value)*:
2.1: 0
2.2: 0
2.3: 0
2.4: 0
2.5: 0
2.6: 0
Time zone entry from internal
table or from list sent from time
zone server (binary value):
2.1: 1
2.2: 2
2.3: 4
2.4: 8
2.5: 16
2.6: 32
2.7
ON
1 2 3 4 5 6 7 8
1
ON
1 2 3 4 5 6 7 8
2
Multicast address range
239.192.54.1-15
resp.
FF38::EFC0:3601-360F
(selection 1..15 resp. 0x1-
0xF with switches 1.5 to
1.8)
Multicast address range
239.251.34.1-15
resp.
FF38::EFFB:2201-220F
(selection 1..15 resp. 0x1-0xF
with switches 1.5 to 1.8)
2.8
ON
1 2 3 4 5 6 7 8
1
ON
1 2 3 4 5 6 7 8
2
Synchronization by NTP
server in the network.
Master mode
.
Slave mode
: Synchronization
by master movement
* Internal time zone 0 = UTC. With external time zone server, the value 0 means “undefined”.