File: SM1280_r7eng - April 2017 - Technical note: SM1280
page 13 of 27
SM 1280
SM 1280
In case the program
sRecLoad.exe
sends data whithin 2
seconds, the microprocessor bootloader stores the new data
on the internal flash memory, installing the new release, and
automatically executes it when the download is done.
Internal
settings
The SM1280x comes in the default settings, and no setting
is required; nevertheless some working parameters can be
modifyed using internal dip-switches.
WARNING: dangerous voltages are present inside the unit,
only trained personal can modify internal settings.
Always switch-off the unit before opening any panel, and
leave at least one minute
DIP-SWITCH #1
(on board M416.x): allows to override some
external alarms, as follow
SW1-
1
if set to ON disables ARC DETECTOR alarm.
SW1-
2
if set to ON disables MAGNETRON THERMAL alarm
SW1-
3
if set to ON disables AIR FLOW alarm
SW1-
4
if set to ON disables H
2
O FLOW alarm
SW1-
5
if set to ON disables INTERLOCK input
SW1-
6
if set to ON disables MICRO CARTER alarm
SW1-
7
if set to ON inhibits the automatic opening of the
interlock relay from the CPU in case of alarm. If it is ON, only
the opening of the MICRO CARTER switch can de-energize
the interlock relay, cutting in this way the power to the head
and leaving the head in a safe condition.
SW1-
8
– not used.
SW2
NORMAL OP.
HARDWARE
FIXED
TEST
FIELDBUS
PM60
H3881
ON OFF
ON OFF
ON OFF
ON OFF
YJ1600
ON OFF
id26042234 pdfMachine by Broadgun Software - a great PDF writer! - a great PDF creator! - http://www.pdfmachine.com http://w
ww.broadgun.com
CPU POWER
HEAD INTERFACE POWER
PLC INTERFACE POWERING
HEAD INTERFACE (CONN#2)
HEAD POWER OUT (CONN#4)
230Vac BOARD POWER
LED BOARD
FIELDBUS INTERFACE
RS232 INTERFACE
M416.1 CONNECTORS, TEST-POINTS, LEDS
TRIMMERS, DIP-SWITCHES, JUMPERS
DIP-SWITCH#2
DIP-SWITCH#1
FILAMENT VOLTAGE ADJ.
PTC ON HEATSINK
FAN POWER
DRIVER COMMAND
PARAMETERS SENSING
CONTROL I/O (CONN#5)
id32384187 pdfMachine by Broadgun Software - a great PDF writer! - a great PDF creator! - http://www.pdfmachine.com http://www.broadgun.com
DIP-SWITCH #2
(on board M416.x)
Switches
1
and
2
(SW2-1 and 2-2) select the type of filament
cut-back curve according magnetron specs: see the following
table.
SW2 - 2 SW2 - 1
Magnetron type
0
0
YJ1600
National
/ E 3327
Toshiba
0
1
H3881
Hitachi
1
0
PM60
Panasonic
1
1
Filament fixed @5V
SW2-
3
if set to OFF enables the external control of the unit, set
to ON enables the fieldbus control.
WARNING: in this case, if no fieldbus interface is present
or if no communication is present on the bus, an alarm is
generated.
SW2-
4
must be set to OFF for normal operation
, if set to ON
enables the hardware test of the M416 board.
WARNING: don’t enable this switch: the use is limited to
trained personal only and for test purposes.
(DIP-SWITCH #1)