    File: SM1280_r7eng - April 2017 - Technical note: SM1280

  

       

  

                                                                                                   

page 9 of 27

             SM 1280 

             

SM 1280

 

Note that each equipment has its own fan which intake approx 
200 m³/h: the outlet of the exhaust air is on rear panel, the 
inlets on the front panel.

When designing a board to house several units we recommend 
to adopt the following design criteria:
1. use a standard 19” wide enclosure with a depth of 800 mm 
(32”);
2. allow free intake of the cooling air from the front of the 
cabinet and exhaust air from back panel throu the top of the 
cabinet or the back side;
3. in case of ambient air with high degree of dust and moisture,   
install a proper air conditioner; if you cannot do this, then  you 

have to use suitable air filters and instruct the user about their 

cleaning;
4. provide a separation between the air intake duct and the air 
outlets, in order to avoid air-recyrculating;

Handling instructions

The equipment weight is 35 kg (77 lbs). Always lift from the 
bottom and use an adeguate rugged support to avoid personal 
injury and damage to equipment itself.
In case of shipping,  package  with the original package or use 

a wooden case and a proper filler: movement of the equipment 

inside the package must be avoided.

Warning for handling:

 use handles only for help during    

installation. 

Never use handles to lift  the rack: the handles 

don’t withstand the off-center weight of the rack!
To lift  always lean the rack over a proper supporting base.

Wiring   instructions

The  SM1280 must be installed and serviced only by quali-

fied personnel acquainted with the regulations covering the 

application. For safety operations the following rules must be 
adopted:

I)  The equipment must be grounded through the connector  #1 
using pin 4 (see the wiring diagram at page 15, 16).
II) Connect the ground screw on panel rear (indicated by 
“ground” symbol) directly to the remote microwave generator 
head by a separate yellow/green wire gauge 2.5 mm².
III) The  main supply must be provided through connector #1: 
connect  phases according to schematic at page 15 & 16: the 
connector’s pins for model T & U can accept wires with gauge 
up to 4 mm²; the connector’s pins for model D can accept 
wires with gauge up to 10 mm²; 

Warning: this connector is not intended for live insertion of 
the unit: an external tripolar breaker must always be pro-
vided, and the unit must be switched off before inserting/
unplugging of the connector.

IV)  The connector #4, with 14 pins, brings the head’s signals 
to the equipment. Use wires with max gauge of 1.5  mm², refer 
to wiring diagram at page 17.

V) The connector #5 is the

 high voltage output

 and must be 

connected to magnetron’s cathode, usually marked with the 
symbol “FA” on the magnetron’s teminal. The voltage value is 
near -8 kV .Use a proper insulated cable with working voltage 
>10 kVdc and minimum gauge of  0.25 mm²; protect the wire 
with sheating (armoured if appropriate).
Assemble the wire into plug according to professional rules. 
The reliability of the equipment starts from the h.v. connec-
tions.
ALTER may supply the HV cable with lenght on request.
VI) The connector #3 provides the power supply for the 

filament transformer (usually located near the magnetron), the 

magnetron fan and a warning lamp. Use wires wih max gauge 
1.5 mm². Refer to wiring diagram at page  17;
VII) The “D” type female connector #6 has 25 pins and brings 
the I/O signals to the equipment. Refer to wiring diagram at 
page 18.
VIII) The CONN# 8 is present only in version 1 and 51. The 

type of socket depends on the fieldbus interface:

 

- RJ 45 on Ethernet-Modbus TCP

 

- 9 pin “D” on CANopen/Profibus

IX) The “D” type female connector RS232 has 9 pins and it’s a 
standard serial port, that can be used to upgrade of the software 
from a PC, or to retrive internal data through FrontPanel GUI. 
Look the pin-out at page 14.
X) The user must provide external cut-off device, to protect the 
SM1280  from short-citcuit and thermal runaway; this external 
protection device  must also allow to switch-off the main line 
for maintenance operations.
XI) The external circuit breaker must be a 3-poles current limi-
ter breaker and must comply the norm EN61010-1.
XII) The external circuit breaker must be in close proximity of 
the equipment and within easy reach of the operator.
XIII) The external circuit breaker must be marked as the 
disconnecting device for the SM1280.
XIV) The connector #1 must never be used as a switch-off 
device.

Failure to comply with these instructions may involve con-
siderable risks for the staff responsible for checking and 
using the equipment, as well as the risk of general malfunc-
tions of the equipment itself.

Содержание SM 1280

Страница 1: ...SM1280D for line 3 x 208V SM1280T for line 3 x 400V SM1280U for line 3 x 480V SWITCHING POWER GENERATOR WITH EMBEDDED MICROCONTROLLER FOR 6 KW MAGNETRON TECHNICAL NOTE issue April 2017 SM 1280...

Страница 2: ...Cover Rear...

Страница 3: ...ioni degli Stati membri relative al materiale elettrico destinato ad essere adoperato entro taluni limiti di tensione 2014 30 UE Harmonisation of the laws of the member States relating to electromagne...

Страница 4: ...ollowing Directive rules this WEEE is not a municipal waste and should be collected separately according to rules of your country the symbol means that this WEEE cannot be disposal in the same place a...

Страница 5: ...d by persons acquainted with the regulations covering the application The equipment described in this manual has been classified as industrial scientific and medical ISM radio frequency equip ment and...

Страница 6: ...t provide a proper cooling flow the cooling air enter into the unit from the front side it passes through the internal circuits and components then it goes out from the back The intake air flow is app...

Страница 7: ...ICH EINEN SCHLOG HOLEN ATTENZIONE LA MANUTENZIONE DEVE ESSERE FATTA DA PERSONALE QUALIFICATO RISCHIO DI SCARICHE ELETTRICHE ALL INTERNO COLLEGARE ALLA TERRA DEL GENERATORE REMOTO VERBINDER DIRECT MIT...

Страница 8: ...V output 3 because the SM1180 had a 4 pole LH type connector and the SM1280 uses the single pole GES type HV connector The back panel of vers 22 see below has the same connetor style size and pin out...

Страница 9: ...Frequency kW MHz 6 2450 Typical YJ1600 H3881 PM60 AM3881 E Selectable filament backdown curve for the specific tube Enabling signal digital input Vdc 24 Range 5 30 ON OFF output alarm reset Input Z 4k...

Страница 10: ...for industrial use only not for laboratory use and user must respect the wiring norms and prescriptions as described into next paragraph Wiring instruction The equipment cannot operate cantilevered i...

Страница 11: ...nnector is not intended for live insertion of the unit an external tripolar breaker must always be pro vided and the unit must be switched off before inserting unplugging of the connector IV The conne...

Страница 12: ...e unit enters in Stand By mode stand by it s a waiting state the unit is powered but not ready as the magnetron filament is not powered all the wor king parameters can be setted from Operator Panel th...

Страница 13: ...e Display versions have a graphic display can be driven manually via the front panel controls The status of the equipment and all the relevant information to the user are provided through the graphic...

Страница 14: ...new program is stored but be sure no enable signal is active when upgrading The upgrade of the firmware embedded in the SM1280 is released as a zip archive named program_name zip Unpacking the zip ar...

Страница 15: ...g the head in a safe condition SW1 8 not used SW2 NORMAL OP HARDWARE FIXED TEST FIELDBUS PM60 H3881 ON OFF ON OFF ON OFF ON OFF YJ1600 ON OFF id26042234 pdfMachine by Broadgun Software a great PDF wri...

Страница 16: ...units A value from 1 to 99 can be set while node 00 is usually reserved and must not be used consult the specific software documentation The bus is based on a network interface device named AnyBus Com...

Страница 17: ...ng the output in the state they were On contrary if the Process Active TimeOut value consult the software documentation for the specific bus has been set to a value greater than zero it stays in Proce...

Страница 18: ...page 16 of 27 File SM1280_r7eng April 2017 Technical note SM1280 SM 1280 Connector 1 wiring vers 0 1 2 22...

Страница 19: ...File SM1280_r7eng April 2017 Technical note SM1280 page 17 of 27 SM 1280 SM 1280 Connector 1 wiring vers 50 51...

Страница 20: ...page 18 of 27 File SM1280_r7eng April 2017 Technical note SM1280 SM 1280 Connector 3 4 5 wiring all versions except 22 14 13 12 11 7 3 8 4 1 2...

Страница 21: ...rated differently i e the reverse signal may be scaled 0 6000W Forward and Reverse Power Monitor if signals are availables Magnetron voltage and current Monitor default setting CONN 6 Forward Power 10...

Страница 22: ...17 Technical note SM1280 SM 1280 RS232 connector wiring all versions id32273156 pdfMachine by Broadgun Software a great PDF writer a great PDF creator http www pdfmachine com http www broadgun com XX...

Страница 23: ...File SM1280_r7eng April 2017 Technical note SM1280 page 21 of 27 SM 1280 SM 1280 Connector 3 4 5 wiring for version 22 only Typical wiring to our standard head type TM060 61...

Страница 24: ...page 22 of 27 File SM1280_r7eng April 2017 Technical note SM1280 SM 1280 COMPONENT LAYOUT Vers 0 1 2 50 51...

Страница 25: ...10 8 1 Aux contact IA3RV1901 1B 9 1 Main line filter FL50FCD10 10 1 Auxsiliary filter FLFN20601206 11 1 3 pins Socket AMP CPC MOCPC07 2060362 CONN 7 3 male pin AMP type XII 35A MOCPCX 0662614 CONN 7 1...

Страница 26: ...s Plug AMP PLUG 1 7 female pin type XII 35A PLUG 1 pins female pin type XII 60A 22 1 HV inductor 23 1 LV inductor 24 1 Current feedback board M302 800000302 1280 25 1 Air grid 26 1 Field bus board M36...

Страница 27: ...ted if true check for h v spot discharge inside socket plug in case replace them d The filament is cold check filament current with high voltage OFF enable signal OFF h v connector 3 disconnected Chec...

Страница 28: ...ad in case replace the magnetron 10 Rack Error The unit has detected an output current 10 lower than expected usually due by a sudden drop of the main line voltage check the main line 11 Not implement...

Страница 29: ...the input for auxiliary voltage separated from power input with bus like version 1 20 special direct replacement for customized SM1180 300 produced till 2001 22 legacy direct replacement for SM1180 a...