page   8  of  16                                                                                                            File: SG1024_r1eng - April 2017 - Technical note: SG 1024

PM 250 

             

SG 1024 S

olid

 S

tate

 M

icrowave

 G

enerator

until the new program is stored, but be sure no enable signal is 
active when upgrading.

The upgrade of the firmware embedded in the SG 1024 is 

released as a “.zip” archive named “program_name.zip”.
Unpacking the .zip archive you generate:
- a directory named “program_name” containing the micro 
code to be loaded, 
- an executable program named “SendApplicationProgram.bat
”- and the loader “sRecLoad.exe”.

Once unpacked the .zip program
- enter in the folder “program_name”, 
- switch-on the SG1024
- run 

whithin 2 seconds

 the program 

“SendApplicationProgra-m.bat” (which launches 

sRecLoad.exe 

application)

(This is the maximum time that the microprocessor bootloader 
waits for new code to be loaded).

In case the program 

sRecLoad.exe

 sends data whithin 2 

seconds, the microprocessor bootloader stores the new data 

on the internal flash memory, installing the new release, and 

automatically executes it when the download is done.

Software release

Release no

.

PSU version

Note

1.00

v.2 “Display”

Compatible with Front 
Panel Vers. 7.50

2.10

v. 1 & 2

New CPU/ Enable Bus 
comm/ Full scale 1 kW

POWER ENABLE: it’s a digital input located on pin 4 CONN 
# 2, has value ON/OFF. It must be ON  to go in MW-ON 
status and generate microwave energy. It can be set OFF at 
any time. 

OPERATING FREQUENCY:it is a control parameter. It can 
be set automatically if the Automatic Tuning is enabled, or 
manually otherwise. If the Automatic Tuning is disabled the 
frequency can be set 
- through the display in manual mode, or 

- via software through the USB serial port or the fieldbus 

module (the latter option only for SG 524 vers. 1). It can not 
be set in external mode using a signal.

AUTOMATIC TUNING: is a feature of the unit based on a 
patented algorithm (US patent 6,020,794).
Due to the possibility to change the operating frequency, 
the user can tune his system choosing between two modes. 
The automatic tuning can be enabled either by the display 
in manual mode or via software in remote mode. Once the 
automatic tune is enabled the software performs the algorithm 
when the unit goes in MW-ON status and it runs until a status 
changing occurs. The goal of this function is to perform a real 
time tuning of the load even if it changes continuously.

REVERSE POWER ALARM THRESHOLD: Threshold can 

be set by the user in order to limit the reflected power. This 

threshold can be set freely by the user, depending on the pro-

cess requirement. The unit can bear a total reflection condition 

for a maximum time of 1 second. It can be set through display 

command (and via fieldbus for vers. 1)

INTERLOCK FUNCTION: managed by CONN#2 pin 10-23  
It is an input that must be powered with signal 24V= OK. If 
the signal si removed (= 0 V) an alarm is generated.

Firmware upgrade

The software stored on the CPU  can be upgraded to a newer 
version using the USB port on the unit, connected to a PC.

Important remark

: at power-on, even if a software is already 

stored, the microprocessor enters a “BOOTLOADER” status, 
lasting 2 seconds, during which it is possible to overwrite, 
through the serial USB port, the stored code.
If no new code is loaded within 2 seconds, the previously 
stored one is run.
To upload a new program through the bootloader, simply 
connect the SG 1024 USB port to the PC USB port.

The first time you must install the USB driver through Windows 

Update. During this operation the unit has to be switched OFF.

Once the PC detects the device the firmware of SG 1024 can 

be upgraded.
No external switch must be operated, and the unit does not start 

Содержание SG 1024

Страница 1: ...SOLID STATE MICROWAVE GENERATOR 1000 W 2450 MHZ TECHNICAL NOTE issue April 2017 SG 1024...

Страница 2: ...Cover Rear...

Страница 3: ...tati membri relative alla compatibilit elettromagnetica Conformity to the Directives is assured through the application of the following standards La conformit alle Direttve assicurata tramite l appli...

Страница 4: ...ies products covered by the Directive as a matter of fact it does not perform a function alone must be included into a larger process equipment and it s for stationary use Nevertheless we invite the U...

Страница 5: ...Industrial scientific and medical ISM radio frequency equipment Electromagnetic disturbance characteristics Limits and methods of measurement With reference to Basic Standard EN55011 this equipment is...

Страница 6: ...e The SG 1024 is offered in two versions the Display version with front panel manual commands and PLC interface to control by I O it carries also one USB standard port which allows to drive read data...

Страница 7: ...ency 26 Output power range Wrf 50 1000 Adjustable range 2 100 Max value differs at frequency band limit Output linearity Wrf 20 Forward power Displayed value vs monitor signal Output stability 1 For i...

Страница 8: ...uction for any doubt then power on the unit through your external contactor Once switched OFF wait at least two seconds before setting it ON again The OFF state between two consecutive ON state must l...

Страница 9: ...Troubleshooting table at page 15 for the complete alarm list and relative codes Note the last alarm occured is permanently stored by the CPU even in absence of main line and can be verified using the...

Страница 10: ...be set in external mode using a signal AUTOMATIC TUNING is a feature of the unit based on a patented algorithm US patent 6 020 794 Due to the possibility to change the operating frequency the user can...

Страница 11: ...pages The number enclosed in brackets refers to the small number associated to names of pages in the previous layout 0 1 At POWER ON the unit shows the Logo its name and software version for a moment...

Страница 12: ...power and parts of the circuit on the final power combiner as well as the coaxial socket may be damaged 6 INFO this page shows the last alarm that occured the software version the generator is runnin...

Страница 13: ...4810 1 Preferred size other length on request max 2 m Coax Cable 7 8 with 7 16 Plugs l 1m 441384811 1 Other length on request max 4 m 3 Transition 7 16 to WR340 MWR26 COAX7 16L Aluminum construction F...

Страница 14: ...nitor signals in the range 0 10Vdc pin 2 and pin 3 ground on pin 15 and 16 respectively Forward and Reverse Power Monitor CONN 2 LOCATION Forward Power Wrf 1 Vmon 100 W TBD Pin no 2 return on pin 15 R...

Страница 15: ...m section or ask our Application Note for the protocol implemented Each SG 1024 generator must be associated to an address the two digital rotating switches must be used the left switch sets the tens...

Страница 16: ...nector MOCPC03 2060362 6 1 CPU Board 800000536 B 7 1 DC Power Supply Board 800000538 8 1 Display Board 800000537 9 1 Fan VE8414NGH 10 1 Line breaker with lever IGM22061192003M1 11 1 Lever 12 1 Solid s...

Страница 17: ...Input Malfunction PLL Alarm linked to internal frequency generator the generated driving signal is out of expected value The CPU turns off the power module automatically After the reset operation the...

Страница 18: ...x Plug right angle 7 16 M F p n MWCOAX7 16L Coax cable length 1 m 1 2 p n 441384810 1M0 Coax cable length 1 m 7 8 p n 441384811 1M0 Cable set for input line and signals only p n 441384524 Waveguide to...

Отзывы: