page   14  of  16                                                                                                            File: SG1024_r1eng - April 2017 - Technical note: SG 1024

PM 250 

             

SG 1024 S

olid

 S

tate

 M

icrowave

 G

enerator

Component list 

Pos.

Q.ty Description

P/N

Note

1

1

Main Inductor PFC

42FI518MPB/PFC

2

1

PFC Board

800000540

3

1

Line filter

FLFN20602008

4

1

Fuse diam 6 x 32 mm, 16 A delayed

FU6X32/16A

5

1

Input line connector 

MOCPC03/2060362

6

1

CPU Board 

800000536/B

7

1

DC Power Supply Board

800000538

8

1

Display Board

800000537

9

1

Fan

VE8414NGH

10

1

Line breaker with lever

IGM22061192003M1

11

1

Lever

12

1

Solid state power amplifier 1 kW

80SG10244

13

1

Heatsink bar

462772006

14

2

Fitting, quick-lock type, 1/4 male straight (CBI Staubli)

PNCB1067151

Plug: PNCBI061810 (*)

Layout of main components

 

 (view without PA and heatsink removed) 

 (view with cover removed only) 

14

Note: 

(*)mating plug for quick-lock fitting must be ordered separately 

Содержание SG 1024

Страница 1: ...SOLID STATE MICROWAVE GENERATOR 1000 W 2450 MHZ TECHNICAL NOTE issue April 2017 SG 1024...

Страница 2: ...Cover Rear...

Страница 3: ...tati membri relative alla compatibilit elettromagnetica Conformity to the Directives is assured through the application of the following standards La conformit alle Direttve assicurata tramite l appli...

Страница 4: ...ies products covered by the Directive as a matter of fact it does not perform a function alone must be included into a larger process equipment and it s for stationary use Nevertheless we invite the U...

Страница 5: ...Industrial scientific and medical ISM radio frequency equipment Electromagnetic disturbance characteristics Limits and methods of measurement With reference to Basic Standard EN55011 this equipment is...

Страница 6: ...e The SG 1024 is offered in two versions the Display version with front panel manual commands and PLC interface to control by I O it carries also one USB standard port which allows to drive read data...

Страница 7: ...ency 26 Output power range Wrf 50 1000 Adjustable range 2 100 Max value differs at frequency band limit Output linearity Wrf 20 Forward power Displayed value vs monitor signal Output stability 1 For i...

Страница 8: ...uction for any doubt then power on the unit through your external contactor Once switched OFF wait at least two seconds before setting it ON again The OFF state between two consecutive ON state must l...

Страница 9: ...Troubleshooting table at page 15 for the complete alarm list and relative codes Note the last alarm occured is permanently stored by the CPU even in absence of main line and can be verified using the...

Страница 10: ...be set in external mode using a signal AUTOMATIC TUNING is a feature of the unit based on a patented algorithm US patent 6 020 794 Due to the possibility to change the operating frequency the user can...

Страница 11: ...pages The number enclosed in brackets refers to the small number associated to names of pages in the previous layout 0 1 At POWER ON the unit shows the Logo its name and software version for a moment...

Страница 12: ...power and parts of the circuit on the final power combiner as well as the coaxial socket may be damaged 6 INFO this page shows the last alarm that occured the software version the generator is runnin...

Страница 13: ...4810 1 Preferred size other length on request max 2 m Coax Cable 7 8 with 7 16 Plugs l 1m 441384811 1 Other length on request max 4 m 3 Transition 7 16 to WR340 MWR26 COAX7 16L Aluminum construction F...

Страница 14: ...nitor signals in the range 0 10Vdc pin 2 and pin 3 ground on pin 15 and 16 respectively Forward and Reverse Power Monitor CONN 2 LOCATION Forward Power Wrf 1 Vmon 100 W TBD Pin no 2 return on pin 15 R...

Страница 15: ...m section or ask our Application Note for the protocol implemented Each SG 1024 generator must be associated to an address the two digital rotating switches must be used the left switch sets the tens...

Страница 16: ...nector MOCPC03 2060362 6 1 CPU Board 800000536 B 7 1 DC Power Supply Board 800000538 8 1 Display Board 800000537 9 1 Fan VE8414NGH 10 1 Line breaker with lever IGM22061192003M1 11 1 Lever 12 1 Solid s...

Страница 17: ...Input Malfunction PLL Alarm linked to internal frequency generator the generated driving signal is out of expected value The CPU turns off the power module automatically After the reset operation the...

Страница 18: ...x Plug right angle 7 16 M F p n MWCOAX7 16L Coax cable length 1 m 1 2 p n 441384810 1M0 Coax cable length 1 m 7 8 p n 441384811 1M0 Cable set for input line and signals only p n 441384524 Waveguide to...

Отзывы: