Interface Cables 

Chapter Two:  Installation

 

Interface Cables 

As of January 1, 1996, all products shipped to the European Community must comply with the 
EMC Directive 89/336/EEC, which covers radio frequency emissions and immunity tests.  MKS 
products that meet these requirements are identified by application of the CE Mark.    

    

The 248A valve meets CE Mark requirements, per EMC Directive 89/336/EEC.  To ensure 
compliance when installed, an overall metal braided shielded cable, grounded at both ends, is 
required during use. 

Generic Shielded Cable Description 

MKS offers a full line of cables for all MKS equipment.  Should you choose to manufacture your 
own cables, follow the guidelines listed below: 

1.  The cable must have a 

braided

 shield, covering all wires.  Neither aluminum foil nor 

spiral shielding will be as effective; using either may nullify regulatory compliance. 

2.  The connectors must have a metal case which has direct contact to the cable’s shield on 

the whole circumference of the cable.  The inductance of a flying lead or wire from the 
shield to the connector will seriously degrade the shield’s effectiveness. The shield 
should be grounded to the connector before its internal wires exit. 

3.  With very few exceptions, the connector(s) must make good contact to the device’s case 

(ground).  “Good contact” is about 0.01 ohms; and the ground should surround all wires.  
Contact to ground at just one point may not suffice.   

4.  For shielded cables with flying leads at one or both ends; it is important at each such end, 

to ground the shield 

before

 the wires exit.  Make this ground with absolute minimum 

length.  Refer to Figures 1 and 2, page 9.  (A ¼ inch piece of #22 wire may be 
undesirably long since it has approximately 5 nH of inductance, equivalent to 31 ohms at 
1000 MHz).  After picking up the braid’s ground, keep wires and braid flat against the 
case.  With very few exceptions, grounded metal covers are not required over terminal 
strips.  If one is required, it will be stated in the Declaration of Conformity or in the 
instruction manual. 

5.  In selecting the appropriate type and wire size for cables, consider: 

A.  The voltage ratings; 

B.  The cumulative I

2

R heating of all the conductors (keep them safely cool); 

C.  The IR drop of the conductors, so that adequate power or signal voltage gets to the 

device; 

D.  The capacitance and inductance of cables which are handling fast signals, (such as 

data lines or stepper motor drive cables); and 

E.  That some cables may need internal shielding from specific wires to others; please 

see the instruction manual for details regarding this matter. 

Содержание 248A

Страница 1: ...service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE IN...

Страница 2: ...107428 P1 Rev L 8 06 MKS Type 248A B C Control Valve...

Страница 3: ...n storage or retrieval system except as may be expressly permitted in writing by MKS Instruments Inc Cajon and VCR are registered trademarks of Cajon Company Macedonia OH Kalrez and Viton are register...

Страница 4: ...Interface Cables 8 Generic Shielded Cable Description 8 Setup 10 Dimensions 10 Mounting Instructions 11 Cables 11 Chapter Three Operation 13 General Information 13 Chapter Four Maintenance 15 General...

Страница 5: ...Table of Contents iv Index 27...

Страница 6: ...res Figure 1 Preferred Method To Connect a Shielded Cable 9 Figure 2 Alternate Method To Connect a Shielded Cable 9 Figure 3 Dimensions of a Type 248 Control Valve 10 Figure 4 Typical Valve Assembly E...

Страница 7: ...List of Figures and Tables vi...

Страница 8: ...injury If necessary remove the MFC from the process equipment to adjust the valve Questions concerning the safe handling of toxic or hazardous gases may be answered by consulting your corporate polic...

Страница 9: ...mpatible with the intended use of the instrument Assemble and tighten fittings according to manufacturer s directions CHECK FOR LEAK TIGHT FITTINGS Before proceeding to instrument setup carefully chec...

Страница 10: ...ctly performed or adhered to could result in injury to personnel Caution The CAUTION sign denotes a hazard It calls attention to an operating procedure practice or the like which if not correctly perf...

Страница 11: ...Safety Procedures and Precautions 4 This page intentionally left blank...

Страница 12: ...placed without special tools Adjustment may be required to eliminate leakage across the valve resulting from normal operational wear Replacement is required when wear has become excessive or when it b...

Страница 13: ...strument to MKS should any repair be needed Appendix A Product Specifications lists the specifications of the instrument Appendix B Model Code Explanation describes the instrument s ordering code Cust...

Страница 14: ...orization Number from the MKS Service Center before shipping Please refer to the inside of the back cover of this manual for a list of MKS Calibration and Service Centers Unpacking Checklist Standard...

Страница 15: ...al wires exit 3 With very few exceptions the connector s must make good contact to the device s case ground Good contact is about 0 01 ohms and the ground should surround all wires Contact to ground a...

Страница 16: ...asher Transducer Housing Optional Plastic or Metal Cable Clamp For Physical Strain Relief Figure 1 Preferred Method To Connect a Shielded Cable Example 2 Alternate Method To Connect Cable shown on a t...

Страница 17: ...tup Dimensions Note All dimensions are listed in inches with millimeters referenced in parentheses Table 1 A B in mm in mm 4 VCR 3 37 85 6 3 38 85 9 4 VCO 3 05 77 5 1 4 Swagelok 2 76 70 1 Figure 3 Dim...

Страница 18: ...couple the 248 valve with the minimum practical length of straight tubing to the upstream flow sensor to achieve stable flow control Cables To connect the 248 valve to a Type 250D E or 1250 controlle...

Страница 19: ...Setup Chapter Two Installation 12 This page intentionally left blank...

Страница 20: ...ing the inlet pressure up to the maximum allowed This extends the maximum flow control range from approximately 3X 10K sccm range to 250X 10 sccm range Decreasing the outlet pressure increases the flo...

Страница 21: ...General Information Chapter Three Operation 14 This page intentionally left blank...

Страница 22: ...o Figure 4 page 16 as needed Note Turn the orifice 5 to 10 at a time each time observing a change in leakage Turn the orifice an additional 10 to 15 beyond the threshold of acceptable leakage Excessiv...

Страница 23: ...apter Four Maintenance 16 Note The drawing above is provided for reference purposes only Disassembly of the valve will void its warranty For maintenance please contact MKS Instruments Inc and obtain a...

Страница 24: ...th O rings see 10 6 Orifice Assembly without O rings 7 Swagelok Fitting 8 Socket Head Screw 8 32 x 0 50 9 Hex Nut 7 16 14 10 O Ring Viton Size 2 016 11 O Ring Viton Size 2 009 12 O Ring Viton Size 3 9...

Страница 25: ...Note the position at removal Replace the parts if the cover is damaged or the coil is an open circuit 3 Remove the four 8 32 screws holding the Collar to the Body 4 Remove the Collar and Center Shaft...

Страница 26: ...nstall a new O ring furnished with the replacement Armature Plug Assembly on the Center Shaft Assembly and install this assembly into the Body and onto the main spring 5 Install the collar and the fou...

Страница 27: ...Assembly Chapter Four Maintenance 20 This page intentionally left blank...

Страница 28: ...amage should be reported to the carrier and MKS Instruments immediately If it is necessary to return the unit to MKS obtain an RMA number Return Material Authorization Number from a MKS Service Center...

Страница 29: ...General Information Chapter Five Repair 22 This page intentionally left blank...

Страница 30: ...mum Inlet Pressure2 150 psig Maximum Throughtput 1 atmosphere at inlet 50 slm maximum valve range configuration Minimum Controllable Flow Rate 0 2 F S 100 sccm 0 1 F S 100 sccm to 10 000 sccm 2 F S fo...

Страница 31: ...General Information Specifications 24 This page intentionally left blank...

Страница 32: ...s follows XXXXX Y Z where Type Number Fittings Seals Y Z Full Scale Range XXXXX Type Number This designates the model number of the instrument 0248A Full Scale Range XXXXX The full scale range is indi...

Страница 33: ...Code Swagelok tube standard S Cajon 4 VCR male optional R Cajon 4 VCO male optional G Seals Z Four types of seals are available designated by a single letter code Ordering Code Viton standard V Neopre...

Страница 34: ...s 8 M Maintenance cleaning 18 disassembly 18 inspection 18 orifice 15 Manual organization 6 Messages definitions of 3 Model code 25 Mounting instructions 11 R Range 25 Returning the product 6 7 21 S S...

Страница 35: ...service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE IN...

Отзывы: