![Mitsubishi TDJ300D Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/mitsubishi/tdj300d/tdj300d_service-manual_1809711014.webp)
(3)
Load so as to allow cool air circulating every
corner of the storage.
To circulate cold wind, the clearance between the
cargo and room wall must be 30mm or more on
both sides and the following values on the rear
side, front side and floor except the blow-out area
from the ceiling evaporator.
The values in ( ) are applicable for TDJ430D.
(4)
Make the upper side of the load as flat as can be.
(5)
After loading, operate the refrigeration unit.
7.3
Unloading
(1)
Perform unloading after stopping the
refrigeration unit.
(2)
Opening the door of the storage once will make
the inside temperature going up momentarily, so
open and close the door quickly so as to not let the
cool air out.
(3)
When loading and unloading, make sure to use a
curtain in order to keep outside air from coming in
and cool air going out.
7.4
Caution to be taken for the usage
(1)
In case of using a refrigerator freight truck as a
refrigerator for a long time consecutively, make
the entire indoor temperature as high as a plus
degree and melt the ice completely.
(2)
Operate the refrigeration unit more than 15
minutes once in 3 or 4 days even if the unit is not
used for a long period of time.
(3)
Avoid using only either the engine of a truck or the
motor of a unit for long. If one of them is not
going to be used for long, make sure to operate
either of them more than 15 minutes once in every
3 or 4 days.
Remarks: Operation procedure operate the unit for about
15 minutes, After switching "ON" and "OFF"
repeat at intervals of several seconds.
In case of driving engine operation type operate by
idling condition.
(4)
The display indication of the controller may flicker
due to wireless (wireless of both our manufactured
vehicles and other makes). If a wireless in installed
in our vehicle, disconnect it.
(5)
Regarding the power source and voltage of motor
drive:
• In case of standard specification, set up the
power volume which allows a rush voltage on
the refrigeration unit side to be able to secure
more than 180V when the motor is started.
• Motor specification
Standard specification 3-phases AC 220V 60Hz,
380V 50/60Hz, 415V 50Hz
• In case of using commercial power source, a
measure to cope with electric leakage for power
supply circuit is required.
(6)
Washing
• When washing a vehicle, be careful not to splash
water directly to the electric equipments inside
the refrigeration unit.
• When cleaning the condenser and evaporator
coil, never make a high pressure washing by a
high pressure washing machine as it crushes the
fin. Also never make a steam washing as it
increases pressure inside of the units unusually
and is dangerous.
– 10 –
Содержание TDJ300D
Страница 1: ...99 TD S 001 MITSUBISHI TRANSPORT REFRIGERATION UNIT TDJ300D TDJ430D SERVICE MANUAL...
Страница 74: ...74 3 Outline drawing a Compressor 1 TDJ300D Unit mm Compressor 7 3kg 2 TDJ430D Compressor 13 5kg...
Страница 81: ...c Piping installation 1 Type 1 piping installation 2 Type 2 piping installation 81...