6.2
Other operations
When the refrigeration unit stops (power is supplied),
the following operations are ready.
(1)
Change of inside-container preset temperature
DISPLAY
··· To higher temperature
e
··· To lower temperature
After pressing "display switch", press the switch
or
, and the inside-container preset
temperature will be displayed on the digital
display unit in the blinking mode to select the
inside-container temperature setting mode.
Continuously press the switch, and the preset
temperature will vary.
··· To higher
temperature
··· To lower
temperature
(Continuously press the switch
or
, and the
temperature will continue varying.)
5 seconds after the finger is released from the
switch, the inside-container temperature will be
displayed.
Then, the digital display unit will go out after
other 5 seconds. Thus, it will be completely set.
(2)
Integrated operation time
DISPLAY
e
HOURS
After pressing "display switch", press "hours
switch", and the integrated operation time will be
displayed on the digital display unit.
5 seconds after the finger is released, the inside
container temperature will be displayed. Then, the
digital display unit will go out after other 5
seconds.
Thus, it will be completed.
6.3
Operation of special service switches
When the operation switch is "off", the following
operation is ready.
(1)
How to clear the evaporator operation time
1
Press the display switch.
2
Press the hours switch and temperature setting
switch
together for 4 seconds, and it will be
cleared.
(2)
How to display the fault history
1
Press the display switch and alarm switch together
for 4 seconds, and max. 5 faults which have
occurred will be displayed with the codes in
sequence from the newest one.
2
When the fault history is displayed, press the
alarm switch and temperature setting switch
together for other 4 seconds, and the fault history
will be cleared.
(3)
How to change the defrost timer setting
1
Press the display switch and defrost switch
together for 4 seconds, and the preset temperature
will be displayed.
2
Press the defrosting switch together with the
temperature setting switch
or
, and the
defrosting time will be changed in the range of 1
to 6 hours.
6.4
Operation sequence
(1)
In case of engine drive from a running vehicle
1
Start the engine which drives the car.
2
Turn the operation switch to "ON".
(When the operation switch comes "ON", the
operation lamp (green) will come on.)
3
Setting of inside-container temperature
Press either temperature setting switch
or
,
and the inside-container setting temperature on the
digital display unit will blink to indicate the
inside-container temperature setting mode.
Keep the switch pressed as it is, and the setting
temperature will vary.
··· To higher
temperature
··· To lower
temperature
(Continuously press the switch
or
, and the
temperature will continue varying.)
Keep the temperature setting switch pressed, and
release the finger from the switch when the
temperature indicated on the digital display unit
reaches the inside container pressure temperature
(transportation temperature).
After 5 seconds, the digital display unit will return
to display the inside-container temperature. Thus,
the inside-container temperature setting mode will
be completed.
▼
▲
Every push of the switch
changes the temperature
by 1°C.
▼
▲
▼
▲
▼
▲
▼
▼
▼
▲
Every push of the switch
changes the temperature
by 1°C.
▼
▲
▼
▲
▼
▲
– 7 –