![Mitsubishi SRC92ZL-S Скачать руководство пользователя страница 34](http://html1.mh-extra.com/html/mitsubishi/src92zl-s/src92zl-s_technical-manual-and-parts-list_1808149034.webp)
-
-
'12 • SRK-T-130
'09•SRK-DB-087D
(6)
ޓ
Flap and louver control
(a) Flap
(b) Louver
(c) Swing
(d) Memory flap (Flap or Louver stopped)
(e) When not operating
COOL , DRY, FAN
Remote control
display
HEAT
Approx. 5°
Approx. 25°
Approx. 25°
Approx. 40°
Approx. 35°
Approx. 50°
Approx. 80°
Approx. 55°
Approx. 60°
Approx. 80°
Angle of Flap from Horizontal
Center installation
Remote control
display
Angle of Louver
Left Approx. 50° Left Approx. 20°
Center
Right Approx. 20° Right Approx. 50°
In HEAT operation
In COOL, DRY, FAN operation
Approx. 35°
Approx. 80°
Approx.
5°
Approx. 60°
(Swing)
(Flap stopped)
(Louver stopped)
(Swing)
(i)
(ii)
(5) Selection of the annual cooling function
(a) The annual cooling function can be enabled or disabled by means
of the jumper wire (J172) on the indoor unit PCB and the dip switch
(SW2-4) on the interface kit (option) PCB.
Note: () Default states of the jumper wire (J) and the interface kit at the shipping from factory –On the
PCB, the dip switch (SW-) is set to enable the annual cooling function.
() To cancel the annual cooling setting, consult your dealer.
(b) Content of control
(i)
If the outdoor air temperature sensor (TH) detects below °C, the indoor unit
speed is switched to th step. (It is not possible to change.)
(ii)
If the outdoor air temperature sensor (TH) detects higher than °C, the indoor
unit speed is changed to the normal control speed.
Jumper wire
(J)
Interface kit
(SC-BIKN-E)
SW-
Function
Shorted
ON
Enabled
Shorted
OFF
Disabled
Open
ON
Disabled
Open
OFF
Disabled
Jumper wire (J172)
ON
5
7
OFF
Outdoor air temperature ( C)
Содержание SRC92ZL-S
Страница 2: ...TECHNICAL MANUAL...
Страница 8: ...12 SRK T 130 3 Remote control a Wireless remote control Unit mm 60 17 3 150...
Страница 55: ...53 12 SRK T 130 Service data record form 47...
Страница 75: ...73 12 SRK T 130 3 Super link E board SC ADNA E F SL2NA E and SL3N AE BE to control...
Страница 76: ...74 12 SRK T 130...
Страница 77: ...75 12 SRK T 130 PARTS LIST INDOOR UNIT SRK92ZL S OUTDOOR UNIT SRC92ZL S...
Страница 81: ...79 12 SRK T 130 MEMO...
Страница 84: ...82 12 SRK T 130 CRBE0347 5 14 15 13 13 15 16 2 3 4 6 12 15 9 10 7 11 15 15 8 1 2 0 55...
Страница 86: ...84 12 SRK T 130 CRBE0348 5 1 17 6 2 3 16 9 4 18 14 19 10 8 15 7 12 13 61 1 2 11 5 3 6 55...
Страница 88: ...86 12 SRK T 130 CRBE0349 23 10 5 6 6 5 11 22 21 20 14 18 17 19 16 15 2 1 3 7 8 4 7 8 9 13 12 2 11 0 1 24 5514...
Страница 90: ...88 12 SRK T 130 CRBE0350 CONTROL UNIT 18 15 3 5 6 7 20 7 19 14 13 4 10 9 12 11 1 2 17 16 8 CONTROL PARTS SET...