5.4 CC-Link IE Controller Network, MELSECNET/H, and Ethernet Instruction
5.4.3 WRITE instruction
5-105
5
QCP
U
IN
S
T
RUCTI
O
N
DE
TA
IL
S
J_
W
R
ITE
, G_
W
R
IT
E
J_WRITE, G_WRITE
[5]
Target station No.
Specify the station number of the target station.
(1) Station number specification
To increase the data reliability when the station number is specified,
executing the instruction with setting Execution/Error completion type
(
[0]) to '1: With arrival confirmation' is recommended.
(2) Group specification
81
H
to A0
H
: All stations in group numbers 1 to 32
(Setting is available when Execution type is set to '0: Without
arrival confirmation' in
[0].)
(3) All stations specification
FF
H
: All stations of the target network number (Except the host
station.)
(Setting is available when Execution type is set to '0: Without
arrival confirmation' in
[0].)
To specify a group or all stations, set '0000
H
' or '03FF
H
' for Target
station's CPU type (
[3]).
1 to 120,
81
H
to A0
H,
FF
H
User
[6]
–
(Fixed value)
0
User
[7]
Number of resends
For instruction execution
Specify the number of resends when the instruction is not completed
within the monitoring time specified in
[8]. (Setting is available when
Execution type is set to '1: With arrival confirmation' in
[0].)
0 to 15
User
At instruction completion
The number of resends (result) is stored. (Setting is available when
Execution type is set to '1: With arrival confirmation' in
[0].)
–
System
[8]
Arrival monitoring time
Specify the monitoring time required for instruction completion. (Setting
is available when Execution type is set to '1: With arrival confirmation' in
[0].)
If the instruction is not completed within this time, it is resent by the
number of times specified in
[7].
0 to 32767
User
Device
Item
Setting data
Setting range
Setting side
*1
S1
Ethernet
MELSECNET/H
1 to 64
CC-Link IE
controller network
Universal model QCPU
1 to 120
High Performance model QCPU 1 to 64
○
S1
○
S1
Gr
oup No.1
・・・
81
H
Gr
oup No.2
・・・
82
H
Gr
oup No.32
・・・
A
0
H
to
○
S1
○
S1
S1
S1
○
S1
○
S1
○
S1
S1
○
S1
○
S1
Description
Setting value
Ethernet
0 to TCP retransmission
timer value: Monitoring is
performed by the TCP
retransmission timer value.
(TCP retransmission timer
value + 1) to 16383:
Monitoring time (unit:
second)
0 to 16383
MELSECNET/H
CC-Link IE
controller network
0: 10 seconds
1 to 32767: 1 to 32767
seconds
0 to 32767
Содержание QCPU