- 5 -
Model
Power source
kW
*1
Heating capacity
kcal / h
BTU / h
kW
A
W.B
*1
(Nominal)
*1
Power input
Current input
for outdoor unit
Temp. range of
W.B
-
heating
for PWFY
kW
*2
Cooling capacity
kcal / h
BTU / h
kW
A
D.B
*2
(Nominal)
*2
Power input
Current input
for outdoor unit
Temp. range of cooling
D.B
-
for PWFY
Total capacity
Model / Quantity
Connectable
outdoor unit
/heat source unit
Sound pressure level (measured in anechoic room)
dB<A>
mm(in.)
mm(in.)
Diameter of
refrigerant pipe
mm(in.)
mm(in.)
Diameter of
water pipe
mm(in.)
mm
Field drain pipe size
External finish
External dimension H × W × D
in.
kg(lbs)
Net weight
Circulating water
Range
Design pressure
Water
R410a
Drawing
Standard attachment
Optional parts
Remark
Note:
Inlet
Outlet
Operation Volume
Liquid
Gas
m
3
/h
MPa
MPa
Accessory
External
Wiring
Document
Unit converter
*2 Nominal cooling conditions (PWFY conditions are indicated in the parentheses.)
*1 Nominal heating conditions (PWFY conditions are indicated in the parentheses.)
Outdoor temp. : 7°CDB/6°CWB (45°FDB / 43°FWB)
Outdoor temp. : 35°CDB (95°FDB)
Pipe length : 7.5 m (24-9/16 ft)
Pipe length : 7.5 m (24-9/16 ft)
Level difference : 0 m (0 ft)
Level difference : 0 m (0 ft)
(Inlet water temp. 30°C
Water flow rate 4.30 m
3
/h)
(Inlet water temp. for PWFY side 30°C
Water flow rate 4.30 m
3
/h)
(Inlet water temp. 23°C
Water flow rate 3.86 m
3
/h)
(Inlet water temp. for PWFY side 23°C
Water flow rate 3.86 m
3
/h)
* Due to continuing improvement, the above specifications may be subject to change without notice.
* Install the outdoor unit (R2-series) in an
environment where the wet bulb temp. will
not exceed 32°C.
* The unit is not designed for outside installations.
* Please do not use the steel material for the water piping material.
* The water circuit must use the closed circuit.
* Please always make water circulate or add the brine to the circulation water when the ambient temperature becomes 0°C or less.
* Please always make water circulate or pull out the circulation water completely when not using it.
Details on foundation work, duct work, insulation work, electrical wiring, power source switch, and
other items shall be referred to the Installation Manual.
10~40°C (50~104°F)
0.015
0.068 - 0.065 - 0.063
21,500
85,300
W.B
WKE94C230
NONE
ø32 (1-1/4'')
PWFY-P200VM-E1-AU
1-phase 220-230-240V 50/60Hz
19,300
22.4
29
25.0
1.8~4.30
1.00
Strainer, Connector, Heat insulation material, 2 × Connector sets, Expansion joint, wire, Flow switch × 1set
PT 1 Screw
Installation Manual, Instruction Book
NO
WKB94L763
31-1/2" (30-15/16" without legs) × 17-3/4” × 11-13/16”
33 (73)
800 (785 without legs) × 450 × 300
4.15
0.015
ø19.05 (ø3/4") Brazed
ø9.52 (ø3/8") Brazed
PT 1 Screw
0.068 - 0.065 - 0.063
76,400
10~35°C (50~95°F)
50~100% of outdoor unit/heat source unit capacity
PUHY-(E)P
•
Y(S)JM-A(1)(-BS)
PUHY-HP
•
Y(S)HM-A(-BS)
PQHY-P
•
Y(S)HM-A
PURY-(E)P
•
Y(S)JM-A(1)(-BS)
PQRY-P
•
Y(S)HM-A
D.B
kcal/h = kW × 860
BTU/h = kW
×
3,412
cfm = m
3
/min
×
35.31
lbs = kg / 0.4536
* The specification data is subject
to rounding variation.
-
-
for heat source unit
-
-
for heat source unit
<Y/HP (ZUBADAN)/R2-series>
<Y/HP (ZUBADAN)/R2-series>
Circulating water temp. : 20°C (68°F)
Pipe length : 7.5 m (24-9/16 ft)
Level difference : 0 m (0 ft)
<WY/WR2-series>
<WY/WR2-series>
Circulating water temp. : 30°C (86°F)
Pipe length : 7.5 m (24-9/16 ft)
Level difference : 0 m (0 ft)
-5~46°C (23~115°F) R2-series
-5~46°C (23~115°F) Y-series
-5~43°C (23~110°F) HP(ZUBADAN)-series
-20~15.5°C (-4~60°F) Y-series
-25~15.5°C (-13~60°F) HP(ZUBADAN)-series
10~45°C (50~113°F) WR2-series
10~45°C (50~113°F) WY-series
10~45°C (50~113°F) WR2-series
10~45°C (50~113°F) WY-series
-20~32°C (-4~90°F) R2-series
* Please do not use it as a drinking water.
* Please do not use ground water and well water.
(3) PWFY-P200VM-E1-AU