5-4. STANDARD OPERATION DATA
The unit of pressure has been changed to MPa based on international SI system.
The conversion factor is : 1 (MPa) = 10.2 (kgf/cm²)
Total
Electrical circuit
Refrigerant circuit
Indoor side
Outdoor
side
Representative matching
SHF
BF
W
kW
Mode
Capacity
Input
Amperes
Phase , Hz
Volts
Current
Discharge pressure
Suction pressure
Discharge temperature
Condensing temperature
Suction temperature
Ref. pipe length
Intake air
temperature
Discharge air
temperature
Intake air
temperature
V
MPa
(
O
f/
F
)
MPa
(
O
f/
F
)
°C
°C
°C
m
°C
°C
°C
°C
°C
Indoor unit
D.B.
W.B.
D.B.
D.B.
W.B.
PLA-SP125BA
PLA-SP140BA
PLA-SP100BA
PLA-SP100BA
PLA-SP125BA
PLA-SP140BA
Cooling
9,400
3.12
Heating
11,200
3.49
Cooling
12,300
4.08
Heating
13,500
3.96
Cooling
13,000
4.98
Heating
15,500
4.83
13.36 / 4.78
2.90
(29.6)
0.92
(9.4)
72.7
48.6
10.1
5
27
19
14.8
35
24
0.74
0.21
15.02 / 5.37
2.57
(26.2)
0.62
(6.3)
75.5
41.4
0.1
5
20
15
43.4
7
6
—
—
17.48/ 6.18
2.68
(27.3)
0.86
(8.8)
67.8
45.5
6.8
5
27
19
13.6
35
24
0.71
0.18
16.95 / 5.99
2.56
(26.1)
0.68
(6.9)
64.5
43.4
1.3
5
20
15
44.2
7
6
—
—
21.65 / 7.58
2.79
(28.5)
0.79
(8.1)
72.7
47.0
4.4
5
27
19
12.9
35
24
0.71
0.14
20.81 / 7.36
2.75
(28.1)
0.64
(6.5)
70.8
47.2
1.0
5
20
15
48.0
7
6
—
—
1 / 3, 50
230 / 400
1 / 3, 50
230 / 400
PUHZ-SP100VHA
PUHZ-SP100YHA
PUHZ-SP125VHA
PUHZ-SP125YHA
PUHZ-SP140VHA
PUHZ-SP140YHA
1 / 3 , 50
230 / 400
0.14
0.94
0.13
0.87
0.15
1.00
0.14
0.94
0.16
1.07
0.15
1.00
Outdoor unit
Phase , Hz
Volts
Input
V
kW
A
1 , 50
230
1 , 50
230
1 , 50
230
A
OCH566A