3.  Installing the indoor unit

Left and left rear piping (Fig. 3-8)

4. Drain hose replacement 

 See 7. Drainage piping work

  Be sure to replace the drain hose and the drain cap for the left and rear left 

piping. Dripping may occur if you forget to install or fail to replace these parts.

Drain cap 

1) Be careful that the drain hose is not raised, and that contact is not made with 

the indoor unit box body. 

2) Securely wrap the felt tape 

3

 starting from the base. (Overlap the felt tape at 

one-half of the tape width.) 

3)  Fasten the end portion of the felt tape 

3

 with vinyl tape. 

Cut off for left piping.

Fig. 3-8

C

D

1)

3)

2)

Fig. 3-9

Fig. 3-10

Fig. 3-11

B

A

C

D

A

C

B

C

A

B

 PKA-RP·HAL

3.5.  Mounting the indoor unit

1. Affix the mount board 

1

 to the wall.

2. Hang the indoor unit on the hook positioned on the upper part of the mount 

board.

Rear, right and lower piping (Fig. 3-9)

3. While inserting the refrigerant piping and drain hose into the wall penetration 

hole (penetration sleeve), hang the top of the indoor unit to the mount board 

1

.

4. Move the indoor unit to the left and right, and verify that the indoor unit is hung 

securely.

5. Fasten by pushing the bottom part of the indoor unit onto the mount board 

1

(Fig. 3-10)

*  Check that the knobs on the bottom of the indoor unit are securely hooked into 

the mount board 

1

.

6. After installation, be sure to check that the indoor unit is installed level.

Mount board 

1

Indoor unit

Hook

square hole

Left and left rear piping (Fig. 3-11)

3. While inserting the drain hose into the wall penetration hole (penetration sleeve), 

hang the top of the indoor unit to the mount board 

1

.

  Giving consideration to the piping storage, move the unit all the way to the left 

side, then cut part of the packaging carton and wrap into a cylindrical form as 

illustrated in the diagram. Hook this to the rear surface rib as a spacer, and raise 

the indoor unit. 

4. Connect the refrigerant piping with the site-side refrigerant piping. 

5. Fasten by pushing the bottom part of the indoor unit onto the mount board 

1

*  Check that the knobs on the bottom of the indoor unit are securely hooked into 

the mount board 

1

6. After installation, be sure to check that the indoor unit is installed level.

Indoor unit 

Packaging cushion

Block of cushion 

9

RG79D479H02_en.indd   5

2012/10/09 (火)   午前 11:37:52

Содержание Mr.Slim PKA-RP35HAL

Страница 1: ...begint MANUALE DI INSTALLAZIONE Per un uso sicuro e corretto prima di installare il condizionatore d aria leggere attentamente il presente manuale ed il manuale d installazione dell unit esterna MANU...

Страница 2: ...changes or dripping water When the room humidity exceeds 80 or when the drainpipe is clogged water may drip from the indoor unit Do not install the indoor unit where such dripping can cause damage Whe...

Страница 3: ...am to the left The hole should incline so that the outside opening is lower than the inside opening Insert a sleeve with a 75 mm diameter and purchased locally through the hole A Sleeve B Hole C Indoo...

Страница 4: ...rking on the mount board as a reference when adjusting the length of the embedded cooling pipe During construction give the length of the extruding pipes etc some leeway A Mount board 1 B Reference ma...

Страница 5: ...ve the indoor unit to the left and right and verify that the indoor unit is hung securely 5 Fasten by pushing the bottom part of the indoor unit onto the mount board 1 Fig 3 10 Check that the knobs on...

Страница 6: ...6 35 17 14 18 12 7 28 49 61 PKA RP HAL Fig 4 3 B A 4 2 Indoor unit Refrigerant and Drainage Piping Sizes Item Model PKA RP35 RP50HAL Refrigerant piping Liquid OD 6 35 1 4 Gas OD 12 7 1 2 Drainage pip...

Страница 7: ...r H Drainage ditch I 5 cm or less between the end of drain pipe and the ground J Drain hose K Soft PVC hose Inside diameter 15 mm or Hard PVC pipe VP 16 Bond with PVC type adhesive Preparing left and...

Страница 8: ...te control cord J Indoor outdoor connection cord K Hook L Ground wire connection portion Warning Never splice the power cable or the indoor outdoor connection cable otherwise it may result in a smoke...

Страница 9: ...ize must comply with the applicable local and national code 2 Power supply cords and Indoor unit Outdoor unit connecting cords shall not be lighter than polychloroprene sheathed flexible cord Design 2...

Страница 10: ...door unit DIP switch settings when using separate indoor unit outdoor unit power supplies only ON OFF 1 2 SW8 3 There are three types of labels labels A B and C Affix the appropriate labels to the uni...

Страница 11: ...he min button twice continuously Pair No 0 blinks 3 Press the temp button to set the pair number you want to set 4 Press the SET button with something sharp at the end Set pair number is lighted for t...

Страница 12: ...ly 6 Complete function selection Direct the wireless remote controller toward the sensor of the indoor unit and press the button E Note Whenever changes are made to the function settings after install...

Страница 13: ...mode then check whether warm air is blown out from the unit 5 Press the FAN button and check whether fan speed changes 6 Press the VANE button and check whether the auto vane operates properly 7 Press...

Страница 14: ...U6 Compressor overcurrent interruption Abnormal of power module 10 U7 Abnormality of super heat due to low discharge temperature 11 U9 UH Abnormality such as overvoltage or voltage shortage and abnor...

Страница 15: ...ng phenomena takes place No signals from the remote controller are accepted OPE lamp is blinking The buzzer makes a short pipng sound Note Operation is not possible for about 30 seconds after cancella...

Страница 16: ...ime displayed is the number of hours the filter has been used since the filter reset was performed 4 Press the FILTER button 5 The data is displayed in C Airflow temperature display example Flashing W...

Страница 17: ...oducts Directive 2009 125 EC This product is designed and intended for use in the residential commercial and light industrial environment The product at hand is based on the following EU regulations R...

Отзывы: