6. Electrical work

6.1.2. Separate indoor unit/outdoor unit power supplies (A-control application)

The following connection patterns are available.
The outdoor unit power supply patterns vary on models.

1:1 System

S1
S2

L1
L2

GR

GR

1
2

L1
L2

S1
S2
S3

S3

A

B

C

G

D

B

E

F

S1
S2

L1

GR

L2

1
2

L1
L2

GR

GR

S1
S2
S3

1
2

L1
L2

S1
S2
S3

S3

A

B

C

D

G

B

E

F

F

* Affix a label B that is included with the manuals near each wiring diagram for the indoor and outdoor units.

A

Outdoor unit power supply

B

Wiring circuit breaker or isolating switch

C

Outdoor unit

D

Indoor unit/outdoor unit connecting cords

E

Remote controller (Only for PKA-A·GA)

F

Indoor unit

G

Indoor unit power supply

Simultaneous twin system

If the indoor and outdoor units have separate power supplies, refer to the table at the
below. Change the indoor unit electrical box wiring refering to the figure in the right
and the DIP switch settings of the outdoor unit control board.

* Affix a label B that is included with the manuals near each wiring diagram for the indoor and outdoor units.

A

Outdoor unit power supply

B

Wiring circuit breaker or isolating switch

C

Outdoor unit

D

Indoor unit/outdoor unit connecting cords

E

Remote controller (Only for PKA-A·GA)

F

Indoor unit

G

Indoor unit power supply

ON
OFF

1

2

(SW8)

3

Indoor unit electrical box connector con-
nection change

Label affixed near each wiring diagram
for the indoor and outdoor units

Outdoor unit DIP switch settings (when
using separate indoor unit/outdoor unit
power supplies only)

Indoor unit specifications

Required

Required

*1. Max. 50 m, 165 ft

*2. The 10 m, 30 ft wire is attached in the remote controller accessory. Max. 500 m, 1500 ft

*3. The figures are NOT always against the ground.

Notes: 1. Wiring size must comply with the applicable local and national code.

2. Use copper supply wires.
3. Use wires rated 300V or more for the power supply cables.
4. Install an earth longer than other cables.

Indoor unit model
Indoor unit power supply
Minimum circuit ampacity
Maximum rating of overcurrent protective device

Indoor unit power supply
Indoor unit power supply earth
Indoor unit-Outdoor unit

*1

Indoor unit earth
Remote controller-Indoor unit

*2

Indoor unit L1-L2

*3

Indoor unit-Outdoor unit S1-S2

*3

Indoor unit-Outdoor unit S2-S3

*3

Remote controller-Indoor unit

*3

PKA

Single 208/230 V, 60 Hz

1 A

15A

×

 Min. AWG16

×

 Min. AWG16

×

 AWG22 (polar)

×

 AWG22 (Non-polar)

AC 208/230 V

DC24 V
DC12 V

Circuit

rating

Wiring

W

ire No. 

×

 size

Connectors (connections when shipped
from the factory are for indoor unit power
supplied from outdoor unit)

Indoor unit power supplied from outdoor unit
(when shipped from factory)

If the indoor and
outdoor units have
separate power
supplies, change the
connections of the
connectors as shown
in the following
figure.

Connectors

  Indoor unit
control board

Separate indoor unit/outdoor unit power
supplies

  Indoor unit
control board

* There are three types of labels (labels A, B, and C). Affix the appropriate labels to

the units according to the wiring method.

 BG79U874H01_en

05.11.30, 9:23

8

Содержание Mr.Slim PKA-A GAL

Страница 1: ...e outdoor unit installation manual thoroughly before installing the air conditioner unit FOR INSTALLER Espa ol MANUAL DE INSTALACI N Para un uso correcto y seguro lea detalladamente este manual y el m...

Страница 2: ...unit as these items can be damaged by temperature changes or dripping water When the room humidity exceeds 80 or when the drainpipe is clogged wa ter may drip from the indoor unit Do not install the...

Страница 3: ...wall you must consult the building contractor A Supporting piece I Bottom left pipe slot knockout hole B Mount board J Bottom right pipe slot 90 mm 3 9 16 inch C Main body K Bottom right pipe slot kno...

Страница 4: ...ipe together Bind the pipes together with vinyl tape at three or more points This will facilitate passing the pipes through the wall 2 Remove the corner box and knock out the knockout holes as necessa...

Страница 5: ...ap liquid and gas pipes with commercially available insulation materials heat resistant to 100 C 212 F or more thickness of 12 mm 1 2 inch or more The indoor parts of the drain pipe should be wrapped...

Страница 6: ...e indoor unit on the drain side Pour water in the drain pan and check that it comes out the drain pipe end After confirmation reinstall the side panel A a b A A B 1 3 2 4 Fig 5 2 4 Installing the refr...

Страница 7: ...ded with the manuals near each wiring diagram for the indoor and outdoor units A Outdoor unit power supply B Wiring circuit breaker or isolating switch C Outdoor unit D Indoor unit outdoor unit connec...

Страница 8: ...el affixed near each wiring diagram for the indoor and outdoor units Outdoor unit DIP switch settings when using separate indoor unit outdoor unit power supplies only Indoor unit specifications Requir...

Страница 9: ...re No size For heat pump models For heat pump models S1 S2 L1 L2 GR GR 1 2 L1 L2 S1 S2 S3 S3 A B C H D B E F S1 S2 L1 L2 GR GR 1 2 L1 L2 S1 S2 S3 S3 A B C H D B E G 1 SW5 Set the DIP switch of the ind...

Страница 10: ...onnected set one to Main and the other to Sub For setting procedures refer to Function selection of remote controller in the operation manual for the indoor unit 6 2 2 For wireless remote controller 1...

Страница 11: ...1 to 04 7 Press the G button and the current set setting number 2 will flash Use the F button to switch the setting number in response to the power supply voltage to be used Power supply voltage 230...

Страница 12: ...st 12 hours before the test run 2 Press the TEST button twice TEST RUN liquid crystal display 3 Press the Mode selection button Make sure that wind is blown out 4 Press the Mode selection button and s...

Страница 13: ...1 P1 Intake sensor error 2 P2 P9 Pipe Liquid or 2 phase pipe sensor error 3 E6 E7 Indoor outdoor unit communication error 4 P4 Drain sensor error 5 P5 Drain pump error 6 P6 Freezing Overheating safegu...

Страница 14: ...o the outdoor unit refrigerant address 0 LED 3 communication between indoor and outdoor units only A control Indicates state of communication between the indoor and outdoor units Make sure that this L...

Страница 15: ...button to deactivate the maintenance mode Stable operation Using the maintenance mode the operation frequency can be fixed and the op eration can be stabilized If the air conditioner is stopped use t...

Страница 16: ...on this manual before handing it to the customer This product is designed and intended for use in the residential commercial and light industrial environment HEAD OFFICE TOKYO BLDG 2 7 3 MARUNOUCHI CH...

Отзывы: