background image

6

1

2

3

2. Parts Names 

 Wireless Remote-Controller 

Note (Only for wireless remote controller):

 When using the wireless remote controller, point it towards the receiver on the indoor unit.

 If the remote controller is operated within approximately 2 minutes after power is supplied to the 

indoor unit, the indoor unit may beep twice as the unit is performing the initial automatic check. 

 The indoor unit beeps to con

fi

 rm that the signal transmitted from the remote controller has been 

received. Signals can be received up to approximately 7 meters in a direct line from the indoor 
unit in an area 45° to the left and right of the unit. However, illumination such as 

fl

 uorescent 

lights and strong light can affect the ability of the indoor unit to receive signals. 

 If the operation lamp near the receiver on the indoor unit is blinking, the unit needs to be in-

spected. Consult your dealer for service. 

 Handle the remote controller carefully! Do not drop the remote controller or subject it to strong 

shocks. In addition, do not get the remote controller wet or leave it in a location with high hu-
midity. 

 To avoid misplacing the remote controller, install the holder included with the remote controller 

on a wall and be sure to always place the remote controller in the holder after use.

Battery installation/replacement

1.  Remove the top cover, insert 2 AAA batter-

ies, and then install the top cover. 

2. Press the Reset button. 

 Outdoor unit 

Two AAA batteries
Insert the negative (–) 
end of each battery 

fi

 rst. 

Install the batteries in 
the correct directions
 (+, –)!

Press the Reset button 
with an object that has 
a narrow end.

Top cover

* For explanation purposes, all of the items 

that appear in the display are shown.

* All items are displayed when the Reset but-

ton is pressed.

Transmission indicator

Timer indicator

Remote controller display

ON/OFF button

Set Temperature buttons

Fan Speed button (Changes fan speed)

Air

fl

 ow button (Changes up/down air

fl

 ow direction)

Mode button (Changes operation mode)

Check button

Test Run button

Transmission area

Operation areas

Timer Off button

Timer On button

Hour button

Minute button

Set Time button (Sets the time)

Louver button (Changes left/right air

fl

 ow direction)

Reset button

Power

Earth

Service Panel

Indoor-Outdoor
Connection wire

Ref. Pipes

Содержание Mr.Slim PCA-RP HAQ

Страница 1: ...u de airconditioner gebruikt MANUAL DE INSTRUCCIONES Lea este manual de instrucciones hasta el final antes de poner en marcha la unidad de aire acondicionado para garantizar un uso seguro y correcto...

Страница 2: ...top operation turn off the power switch and contact your dealer Never insert fingers sticks etc into the intakes or outlets If you detect odd smells stop using the unit turn off the power switch and c...

Страница 3: ...er Manual Manual Manual Filter Normal Long life Oil Filter cleaning indication 100 hr 2 500 hr 100 hr 2 Parts Names PCA RP KAQ Ceiling Suspended Vane Air outlet Air intake Filter Inside of Air intake...

Страница 4: ...ing up the Main menu 5 Backlit LCD Operation settings will appear When the backlight is off pressing any button turns the backlight on and it will stay lit for a certain period of time depending on th...

Страница 5: ...e 2 Appears when the buttons are locked Full mode All icons are displayed for explanation Fri Mode Temp Fan Room Cool Auto Set temp Basic mode Fri Cool Mode Temp Fan Auto Set temp 2 1 5 6 7 8 9 0 1 3...

Страница 6: ...te controller wet or leave it in a location with high hu midity To avoid misplacing the remote controller install the holder included with the remote controller on a wall and be sure to always place t...

Страница 7: ...ted to the same outdoor unit are already operated in a different mode In this case the rest of the unit in the same group can only be operated in the same mode Automatic operation According to a set t...

Страница 8: ...n automatic fan speed is not set at default setting It is not necessary to set for wired remote controller with automatic fan speed at default setting 1 Press the SET button with something sharp at th...

Страница 9: ...ng to move the vanes up and down automatically When set to Step 1 through Step 5 the vane will be fixed at the se lected angle under the vane setting icon This icon will appear when the vane is set to...

Страница 10: ...tion switch heating D Emergency operation switch cooling E Receiver Starting operation To operate the cooling mode press the button D for more than 2 seconds To operate the heating mode press the butt...

Страница 11: ...filter sign is reset the cumulative operation time of all units will be reset The icon is scheduled to appear after a certain duration of opera tion based on the premise that the indoor units are inst...

Страница 12: ...leaning the frame of the oil filter Tools to be prepared Protective goods such as a rubber glove Scrubbing brush or brush Note Avoid using a metal scrubbing brush or brush since the aluminum materials...

Страница 13: ...is emitted from the indoor unit If the indoor temperature and the humidity are high this condition may occur when operation starts During defrosting mode cool airflow may blow down and appear like a m...

Страница 14: ...ler Be sure to provide the dealer with the model name 7 Trouble Shooting Model PKA RP35HAL PKA RP50HAL Power source voltage V Frequency Hz N 230 50 Rated Input Indoor only kW 0 04 0 03 0 04 0 03 Rated...

Страница 15: ...146 1 PAR 31MAA 8 R410A 1 146 2 147 3 151 4 154 5 154 6 155 7 157 8 158...

Страница 16: ...147 PKA RP HAL PCA RP KAQ PCA RP HAQ 3 4 2 100 2 500 100 2 PCA RP KAQ PKA RP HAL PCA RP HAQ...

Страница 17: ...5 6 7 8 9 0 Fri Room Set temp Mode Temp Fan Cool Auto Main Main display Cursor Page Main menu Vane Louver Vent Lossnay High power Timer Weekly timer OU silent mode 7 8 9 0 7 8 9 0 1 2 3 4 5 6 7 F1 8...

Страница 18: ...149 2 Fri Mode Temp Fan Room Cool Auto Set temp Fri Cool Mode Temp Fan Auto Set temp 2 1 5 6 7 8 9 0 1 3 9 4 2 3 4 5 6 7 8 1 2 3 4 5 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 1 8 9...

Страница 19: ...150 1 AAA 2 Reset 1 2 3 2 7 45 AAA Reset Reset ON OFF Test Reset Power Earth Service Panel Indoor Outdoor Connection wire Ref Pipes...

Страница 20: ...at Cool Dry Fan Auto Heat 2 0 C 15 2 0 C 15 15 2 0 C 2 0 C 15 F1 F2 F3 F4 Cool Room Auto Set temp Mode Temp Fan Fri 3 3 Cool Dry Heat Auto Cool Room28 5 Auto Set temp Mode Temp Fan Fri 28 5 0 5 F1 F2...

Страница 21: ...nt mode F1 F2 Auto 1 STAND BY DEFROST 2 3 HEAT 4 DRY 1 SET MODELSELECT A 2 AUTO STOP B 01 3 02 02 ON OFF 2 4 SET MODELSELECT 3 ON OFF TEMP RESET SET CLOCK MODELSELECT FAN VANE TEST RUN AUTO STOP AUTO...

Страница 22: ...ouver Vent Lossnay High power Timer Weekly timer OU silent mode Vane Louver Vent Lossnay Lossnay 152 F1 F2 F3 F4 Fri Swing Off Off Louver Vent Vane Cool Room Auto Set temp Mode Temp Fan Fri F1 F2 F3 F...

Страница 23: ...154 4 1 4 E O SW 5 PKA RP HAL Fig 5 1 Fig 5 2 Fig 5 1 A DEFROST STAND BY B C D E D 2 C 2 D C 2 Fig 5 2 A DEFROST STAND BY OPAH EB l B E EH I C D COOL HEAT 5 STOP 5 COOL HEAT 24 C 24 C 4 5...

Страница 24: ...k Filter information Error information F1 F2 F3 F4 Main menu Filter information Reset Please clean the filter Press Reset button after filter cleaning F1 F2 F3 F4 Filter information Filter information...

Страница 25: ...156 6 1 1 2 A B C D B A D C RP71 3 RP125 4 PCA RP HAQ 1 1 2 1 2 1 2 3 PAC SG38KF 12 4 5 A C B D 3 1 100 2 1 10 50 C 1 PKA RP HAL PCA RP KAQ PCA RP HAQ...

Страница 26: ...157 7 10 1 ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF PLEASE WAIT 3...

Страница 27: ...0 06 0 06 0 06 0 09 0 09 0 11 0 11 0 14 0 14 A 0 29 0 27 0 37 0 37 0 39 0 39 0 42 0 42 0 65 0 65 0 76 0 76 0 90 0 90 230 960 1280 1600 680 2 1 3 10 11 12 14 10 11 13 15 15 16 17 19 16 17 18 20 22 24...

Страница 28: ...ra compilar o ficheiro t cnico o seguinte Vores autoriserede repr sentant i EU som er autoriseret til udarbejdelse af den tekniske fil er f l gende V r EG representant som r auktoriserad att sammanst...

Страница 29: ...C9612 JIS B8616 ISO 5151 T1 et ISO 13523 T1 SVENSKA Engelska r originalspr ket De vriga spr kversionerna r vers ttningar av ori ginalet F RSIKTIGHET K ldmedelsl ckage kan leda till kv vning Tillhanda...

Страница 30: ...ATE Sequential number for each unit 00001 99999 A indoor unit A Month of manufacture 4 5 6 7 8 9 X 10 Y 11 Z 12 1 2 3 Last digit of the company s fiscal year western calendar 2014 4 2015 5 00001 99999...

Страница 31: ...I CHIYODA KU TOKYO 100 8310 JAPAN Authorized representative in EU MITSUBISHI EUROPE B V HARMAN HOUSE 1 GEORGE STREET UXBRIDE MIDDLESEX UB8 1QQ U K 115054 52 1 Please be sure to put the contact address...

Отзывы: