5
¡
LOW TEMP
The unit operates continuously and automatically by controlling airflow according to
room temperature. The air flow is strongest below 15
°
C. The use of LOW TEMP
mode is recommended when the Low temperature indicator is lit.
When the temperature is low, condensation may still form on windows exposed to the outside
air even when LOW TEMP mode is operating
¡
MILDEW GUARD
The unit lowers humidity levels automatically once a day, suppressing mildew growth.
¡
The unit operates intermittently for 2-4 hours a day
(24 hours).
¡
The operating time varies depending on the humidity.
The unit continues to operate when the humidity does not
decrease.
• Humidity 40%
→
Approx. 2 hours
• Humidity 50%
→
Approx. 4 hours
∞
Refrain from turning on ventilation fans or opening windows or doors as this lowers performance.
∞
Mildew growth may still occur due to the fungus type and conditions of the room.
• E.g. Rooms that contain excessive condensation, bathrooms, and places with bad airflow (insides of
closets and behind furniture).
∞
This mode does not remove existing mildew.
∞
Do not use in conjunction with OFF Timer mode. Effects may not be achieved.
Information
Information
¡
HIGH
The dehumidifier operates regardless
of the humidity level. Airflow is strong.
ON
24 hours
Dehumidifies
Dehumidifies
Standby
24 hours
Standby
How is mildew
Mildew is unable to produce new spores (similar to plant seeds) if dried as
mycelia. The Mildew Guard feature applies this principle (However, the
growth suppressed?
spores themselves are resilient to dry conditions.).
“Identification of Aspergillus and Penicillium”
<Research paper by Dr. K. Abe of the Environmental Biology Research Center>
Repeat
¡
EASY DEHUMIDIFYING
The unit operates intermittently controlling the
airflow to remove the damp feeling in the air.
(There is no need to set the humidity level)
When the room temperature is high, the blower
operates to decrease the damp feeling.
The airflow or louvre operation may stop
according to the humidity level.
¡
LAUNDRY
The unit operates for 12 hours and automatically
switches off.
∞
Drain the tank before use.
The unit may stop before the washing dries
because of a full tank.
∞
Do not use in conjunction with the OFF
timer.
The timer may turn the unit off before the
washing dries.
∞
The following conditions prevent clothes
from drying well:
Room temperature below 15
°
C, large
volume of laundry; laundry not spaced well;
clothes of thick fabric and spacious room.
Humidity
level (%)
Room
temperature
(
°
C)
60
50
0
20
27 30
Room temperature is
below 27
°
C - the unit
automatically sets the
humidity level
according to the
temperature.
Room temperature is
above 27
°
C - the unit
lowers the humidity
level to 50%, then
activates the blower.
The dehumidifier is
reactivated when
humidity rises to 60%.
Modes
Information
¡
LOW
The dehumidifier operates regardless
of the humidity level. Airflow is weak.
Содержание MJ-E26VX-A1
Страница 24: ...24 7 4 General Block Diagram ...
Страница 25: ...25 ...
Страница 38: ...38 Parts Catalog Model MJ E26VX A1 Exploded View Electrical Parts 4 B C 7 6 3 E F 8 5 2 1 11 10 9 14 D 13 12 A ...