15
7. Wiring Diagram and Block Diagram
7.1 Wiring Diagram
(1) Current fuse ....................Overcurrent flow caused by degraded electrical parts turns off the power.
Current setting: 2A
(2) Motor protector ................Room temperatures exceeding about 40°C shut down the compressor.
(Overload relay)
The compressor also shuts down when it is locked or otherwise malfunctions,
with current flow exceeding 2.5A.
(3) Control circuitry ...............The room temperature thermistor, on sensing a room temperature below about
0°C, shuts down the compressor.
(4) Thermal fuse ...................The blower shuts down when it is locked or otherwise malfunctions, with its
temperature exceeding 134°C.
Safety Devices
P1
P11
P10
P100
P2
P3
P5
P4
P20
P13
P101
FM
S
C
R
CM
SV
Blue
Blue
Blue
Black
Gray
White
Red
Yellow
Overload relay
Compressor
Solenoid valve
Fan motor
P200
P201
Sensors
(Humidity and room
temperature sensing)
Control board
White
White
White
White
Brown
Brown
Tank full switch
Stepping motor
SM
Gray
Gray
Power supply board
Gray
Gray
Run capacitor
Blue
Brown
Power plug
Thermistor (Tube
temperature sensing)
1 C (defrost)/12 C (end)
Содержание MJ-E26VX-A1