57
Set the air outlet selection switch to
.
Set the air outlet selection switch to
.
Air blows out automatically from the upper and lower air out-
lets as shown in the table below.
COOL
DRY
HEAT
Operation
Air
flow
Conditions
Upper and lower air flow
Room temperature
and set temperature
are different.
Upper air flow
Room temperature is
close to set tempera-
ture, or the air
conditioner has
operated for 1 hour.
Upper air flow only Upper and lower air flow
Air flow temperature
is high.
Upper air flow
Air flow temperature
is low.
(During defrosting
operation, start of
operation, etc.)
NOTE 2 : Set the air outlet selection switch to the end correctly. Otherwise, air outlet cannot be selected as intended.
Description of operation
• Be sure to keep the area around the damper of the lower air outlet free of any objects. If any objects block the normal
operation of the damper, the left operation indicator lamp may blink.
With this function, air comes out simultaneously from the upper and lower air outlets so that the room
can be cooled or heated effectively. This function is set using the switch behind the front grille of the
indoor unit. (This function is available in cooling and heating operation.)
1.How to set to blow out air from the upper
and lower air outlets:
2.How to set to blow out air from the upper
air outlet only:
NOTE 1 : Be sure to turn off the air conditioner before changing the switch setting.
• As for indoor fan motor (upper), refer to "Indoor fan speed control (3-1.2, 3-2.2, 3-3.2)" and
"INDOOR FAN MOTOR CONTROL (3-5.)".
The direction (opening and closing of the damper) and the volume of the airflow from the lower air
outlet are controlled automatically.
2
:
7
:
Indoor fan motor (Lower) in COOL OPERATION
Damper
OPEN
CLOSE
35
:
40
:
Indoor fan motor (Lower) in HEAT OPERATION
Indoor coil thermistor temperature
Damper
OPEN
CLOSE
Difference between
room temperature and
set temperature
during operation
Indoor coil thermistor
temperature
Difference between room temperature and
set temperature during operation
(9) Damper operation
OBT14A--2qxp 06.1.12 1:09 PM Page 57