12
1-9. AREA ( ) SETTING
(1) Press OPERATE / STOP (ON/ OFF)button to start the air conditioner.
(2) Press i-see button. (NOTE 1)
(3) Press AREA button.
Each time the button is pressed, the area is changed in sequence:
NOTE1: AREA setting is only available during i-see control operation.
NOTE2: If AREA setting is canceled, the vertical vane returns to the previously set position before AREA setting.
NOTE3: The horizontal air flow direction (WIDE VANE button), including horizontal SWING, can not be set during AREA setting.
(AUTO)
(LEFT)
(RIGHT)
Cancel
The indoor unit delivers warm air detecting the cold area in the room.
·
If AREA setting is set to AUTO in heating operation, the indoor unit automatically delivers warm air to the area
where the floor/wall temperature is the lowest in the room.
·
If AREA setting is set to AUTO in cooling operation, the indoor unit automatically delivers cool air to the area
where the floor/wall temperature is the highest in the room.
Ex.) In heating operation
Mo
ving of hor
iz
ontal air flo
w direction
Indoor unit
displa
y
NO
TE
·
The horizontal air flow direction changes if i-see Sensor detects approx. 3
;
temperature difference.
·
In AUTO of AREA setting, both right and left lamps are lighted when the room is evenly air-conditioned.
Indication of AREA setting
Day
Night
Warm area
Cold area
Lighted
Not lighted
i-see Sensor moves intermittenly, measuring the floor and wall temperature.
OBT14A--1qxp 06.1.12 1:07 PM Page 12