Mitsubishi FR-E800 Series Скачать руководство пользователя страница 40

40/79 

BCN-P5999-1305-1c 

Type 

Device No. 

Application 

Bit

 

GB17211 

Restoration STEP 3 execution trigger 

GB17220 

Copy STEP 2 execution trigger 

GB17230 

Machine diagnosis STEP 2 execution trigger 

GB17231 

Machine diagnosis STEP 3 execution trigger 

 

GD Devices (Changeable)

 

Type 

Device No. 

Application 

Bit

 

GD65231.b13 

System alarm reset 

GD65290.b0 

Recipe common control read trigger 

GD65290.b1 

Recipe common control write trigger 

GD65293.b0 

Recipe-shared Write-in-progress signal 

GD65293.b1 

Recipe-shared Read-in-progress signal 

Word

 

GD15000 to GD15199 

Parameter selection    parameter No. storage device 

GD15250 to GD15259 

Parameter list    parameter No. storage device (line 1 to 10) 

GD15270 

Bookmark storage execution process order storage device 

GD15281 

Parameter selection recipe record No. storage device 

GD15285 

Parameter list    page No. 

GD15286 

Parameter list    the total number of pages 

GD15297 

Copy process    process execution number 

GD15299 

Copy source recipe ID storage device 

GD15300 to GD15315 

Copy destination recipe ID storage device (station No. 1 to 
16) 

GD15400 

Copy process order storage device 

GD16000 to GD16009 

Bookmark    system area 

GD16010 

Bookmark    registration number 

GD16011 

Bookmark    the total number of pages 

GD16012 

Bookmark    Page No. 

GD16020 to GD16029 

Reference pointer operation result storage device (line 1 to 
10) 

GD16030 

Parameter No. reference pointer storage device 

GD16040 to GD16049 

Parameter No. (line 1 to 10) 

GD16500 

Station  No.  power-failure  backup  record  No.    storage 
device 

GD16501 

Display language back up device 

GD16505 

Power saving effect unit switching 

GD16506 

Cumulative energy saving unit switching 

GD16507 

Rotation speed/machine speed    unit switching 

GD16510 

OP3 lower byte storage device 

GD16520 

AL0 lower byte storage device 

GD16522 

AL100 lower byte storage device 

GD16524 

AL200 lower byte storage device 

GD16526 

AL300 lower byte storage device 

GD16528 

AL400 lower byte storage device 

GD16530 

AL500 lower byte storage device 

GD16532 

AL600 lower byte storage device 

GD16534 

AL700 lower byte storage device 

GD16536 

AL800 lower byte storage device 

GD16560 

Machine diagnosis progress display device 

GD16570 

Display warning switching device 

GD16740 

3-speed operation status    reference pointer storage device 

GD16750 to GD16765 

3-speed operation status (station No.1 to 16) 

GD16800 

Recipe process control device 

GD16810 

Screen switching tab    status display 

GD16820 

Backup process control device 

GD16821 

Backup progress device 

GD16825 

Restoration process control device 

GD16826 

Restoration progress device 

GD16830 

Load characteristics measurement process control device 

GD16831 

Load characteristics measurement progress device 

Содержание FR-E800 Series

Страница 1: ...Mitsubishi Inverter FR E800 Series Sample Screen Manual Mitsubishi Electric Corporation...

Страница 2: ...ustomer using Mitsubishi products 4 Mitsubishi will not be held liable for any damages resulting from the use of the Files or the data extracted from the Files The customer is responsible for all use...

Страница 3: ...atch Monitor 1 to 2 B 12200 to 12201 18 5 1 8 Alarm History Inverter B 12300 19 5 1 9 Machine diag load char meas B 12310 20 5 1 10 Inverter Life Diagnosis 1 to 2 B 12320 to 12321 21 5 1 11 Manual Dis...

Страница 4: ...erter via PLC Ethernet 66 7 4 1 Controller Setting of GOT 67 7 4 2 PLC Side Settings GX Works3 68 7 4 3 Inverter FR E800 E Communication Settings 69 7 4 4 Settings of Sample Screen 69 7 5 Connecting G...

Страница 5: ...No 2020 11 BCN P5999 1305 1c No revision The control No is noted at the lower right of each page Project Data Date Project Data GT Designer3 Description 2020 4 MITSUBISHI_FR E800 E_V_Ver1_E GTX 1 235...

Страница 6: ...6 79 BCN P5999 1305 1c...

Страница 7: ...SYSTEM CONFIGURATION 1 The SD card is used for the recipe function and document display function 2 The battery is used to back up the clock data and the recipe data in the SRAM user area in case of po...

Страница 8: ...lified Outline Font Gothic Alphanumeric Kana Japanese Kanji Chinese Simplified Key Window Design Information Recipe Display Record List Document Display Document Display PDF PDF Search Bookmark functi...

Страница 9: ...GOT Ethernet Standard Port setting Checked GOT IP Address 192 168 3 18 Subnet Mask 255 255 255 0 Extended Port None Wireless LAN None GOT Ethernet Common Setting Item Set value Remarks Default Gateway...

Страница 10: ...n Pr 1426 0 Default value 2 Ethernet function selection 1 Pr 1427 5000 to 5002 5006 to 5008 1 Ethernet function selection 2 Pr 1428 9999 2 Ethernet function selection 3 Pr 1429 9999 2 Ethernet signal...

Страница 11: ...on selection Pr 180 0 Low speed operation command RM terminal function selection Pr 181 1 Middle speed operation command RH terminal function selection Pr 182 2 High speed operation command 4 3 The Ou...

Страница 12: ...ber Switching screen Axis name can be changed to the name specified by the user When changing the axis name edit comment No 1 to 16 of the comment group No 340 3 Notifies users of the alarm occurrence...

Страница 13: ...ches to Manual Display screen 3 Parameters of INVERTER FR E800 Instruction Manual Function is displayed in Startup and Operation 2 Protective Functions of INVERTER FR E800 Instruction Manual Maintenan...

Страница 14: ...again to deselect the registered bookmarked parameters 3 Switches to Manual Display screen Displayed manual 3 Parameters of INVERTER FR E800 Instruction Manual Function 4 Displays the current page num...

Страница 15: ...s of INVERTER FR E800 Instruction Manual Function 3 Displays the current page number and the total number of the pages of Parameter Bookmark Touch the current page number to change the page to display...

Страница 16: ...or incrementing or decrementing the frequency by 1Hz with touch switches on the left and right sides of the value input area the switches can be held down When 3 speed operation is enabled the settin...

Страница 17: ...se Rotation Machine Error Occurring Inverter Fault Lights red when an ALM fault is occurring Remarks When the inverter is in the NET operation mode commands can be input to the inverter by the GOT Whe...

Страница 18: ...B 12200 to 12201 Outline This screen is used to monitor the monitoring items of the inverter connected to the GOT in a batch Description 1 Displays names and the current values of monitoring items 2 S...

Страница 19: ...nance 4 Executes the inverter reset Operates when holding down the switch for 3 seconds Use this switch when performing the inverter reset after completing dealing with the fault failure currently occ...

Страница 20: ...speed minimum and maximum frequency for performing the load characteristics measurement 4 Displays Machine Diagnosis Execution screen 5 Displays the output frequency being measured 6 Sets the upper a...

Страница 21: ...the inverter parts connected to the GOT Description 1 Displays the life information of the inverter parts When reaching the life alarm output level and the inverter outputs the warning is displayed 2...

Страница 22: ...n Search window to search through the PDF file 3 Operates a displayed document Enlarges or reduces the displayed document Scrolls the document to left and right Scrolls the displayed document up and d...

Страница 23: ...ors Description 1 Touch the station to switch the station for monitoring to the touched station 2 Switches to the previously displayed screen Remarks This sample screen uses the station No switching f...

Страница 24: ...ect the station to back up restore 3 Touch the switch to store the parameters of the inverter in the recipe file of the GOT Displays the confirmation dialog at the time of execution 4 Switches to the...

Страница 25: ...after copy Description 1 Selects the copy source station of the recipe function The selected station lights green 2 Executes the copy of the parameter recipe 3 Switches to the previously displayed scr...

Страница 26: ...the execution steps of Backup Execution screen The step during execution and the completed step light sky blue 2 When the process switches to the next step the arrow icon lights white 3 Executes the b...

Страница 27: ...e execution steps of Restoration Execution screen The step during execution and the completed step light sky blue 2 When the process switches to the next step the arrow icon lights white 3 Executes th...

Страница 28: ...iption 1 Displays the execution steps of Copy Execution screen The step during execution and the completed step light sky blue 2 When the process switches to the next step the arrow icon lights white...

Страница 29: ...wing messages are displayed Machine diagnosis completion Machine diagnosis is completed successfully Machine diagnosis abnormality Measurement is completed by an activation of a protective function in...

Страница 30: ...g inverter operation Measurement of the machine diagnosis shall be done while the inverter is stopped During alarm occurrence Measurement of the machine diagnosis shall be done after clearing inverter...

Страница 31: ...and the information of the cursor position when the cursor is displayed in the historical trend graph 5 Displays the beginning position time of the waveform displayed in the historical trend graph Re...

Страница 32: ...he switch to switch the language 2 Displays the current date and time 3 Change the date and time with switches Holding down the switches increases or decreases the numbers consecutively Touch switch t...

Страница 33: ...tem alarms of the GOT currently occurring Description 1 Displays the system alarms currently occurring Maximum 12 system alarms are displayed Touch the displayed system alarm to scroll the message 2 S...

Страница 34: ...ookmark screen is as below How to register parameters in Parameter Bookmark screen Example Register Pr 7 Acceleration time in Parameter Bookmark 1 Touch the registration Regi switch placed on the line...

Страница 35: ...Example Remove Pr 7 Acceleration time from Parameter Bookmark 1 Touch the registration Regi switch placed on the line of Pr 7 Acceleration time in Parameter List screen to deselect 2 Switch to Parame...

Страница 36: ...Characteristics Measurement screen is as below Example Set 10 to Minimum Frequency and 60 to Maximum Frequency and perform the load characteristics measurement 1 Set detection range frequency of load...

Страница 37: ...1c 3 Machine Diagnosis Execution screen is displayed Then touch OK The inverter starts the load characteristics measurement 4 STEP3 is displayed when the load characteristics measurement is completed...

Страница 38: ...the value touch the value to change it manually 6 Set the detection widths threshold velue of upper limit and lower limit warnings compared with the standard values for load characteristics The defau...

Страница 39: ...arm batch clear operation trigger GB16716 Inverter reset operation trigger GB16720 Machine diagnosis measurement start trigger GB16721 Machine diagnosis forward rotation command ON trigger GB16735 Rec...

Страница 40: ...okmark Page No GD16020 to GD16029 Reference pointer operation result storage device line 1 to 10 GD16030 Parameter No reference pointer storage device GD16040 to GD16049 Parameter No line 1 to 10 GD16...

Страница 41: ...rage GD65300 to GD65305 Digital switch for clock Double word GD16700 Frequency display device 1 GD16702 Frequency display device 2 GD16704 Frequency display device 3 GD16850 Logging cursor information...

Страница 42: ...igned BIN16 GD65221 Language switching device s16_Com_CngSytmLanDv Signed BIN16 GD65222 System language switching device s16_Com_StmInfRd Signed BIN16 0 2 GD65231 System information read device s16_Co...

Страница 43: ...displays faults are registered The alarm names are registered to comment No same as data code 340 Axis names displayed with the station numbers are registered When connecting the GOT to the inverter i...

Страница 44: ...Setting screen Project script No Screen script No No Object script Yes ID 10062 B 12900 Script parts Yes Placed on the upper left of each screen B 12000 to 12900 B 14103 to 14301 and B 32000 Position...

Страница 45: ...to the following system configuration Example When utilizing this sample screen as the connected controller CH2 in the user s project data which sets the MELSEC iQ RCPU to the connected controller CH1...

Страница 46: ...of Controller Setting A CH of Controller Setting is occupied by utilizing this sample screen in the project data When all channels CH1 to 4 are used in the project data before utilizing this sample s...

Страница 47: ...en the Sample Screen Installed to GT Designer 3 2 Add the settings of the inverter to CH2 of Controller Setting in this sample screen and user s project data to utilize the inverter as CH2 of the cont...

Страница 48: ...Sample Screen Installed to GT Designer 3 Select Project and then Utilize Data and perform the operations below to open the sample screen 1 Set Sample project to Target 2 Select Detail and input E800 t...

Страница 49: ...rocedures below How to change Controller Setting of this sample screen from CH1 to CH2 1 Go to Common Controller Setting and check Use CH2 to perform the setting of the connected inverter Because the...

Страница 50: ...on No Switching which is connected to the inverter in Station No Switching 5 Select Project and then Save As Project to save as another project data How to set CH2 of Controller Setting in user s proj...

Страница 51: ...ta Project 3 Select Browse and open the project data created in 6 2 2 Preparation before Utilization 4 Check the following items Item Controller Setting Check Station No Switching Base Screen Check al...

Страница 52: ...52 79 BCN P5999 1305 1c 5 Set Retain the same No to Destination and select Utilize 6 Perform 6 3 Works after Utilization...

Страница 53: ...gn Device Default Value 1 Application u16_Com_CngBsDv Unsigned BIN16 GD65200 Screen switch device base screen s16_Com_StmInfRd Signed BIN16 0 2 GD65231 System information read device s16_Com_StmInfWt...

Страница 54: ...l Setting Change and add the following settings in the project data after utilization 1 Screen Switching Window Setting Base Screen Change the screen switch device of Base Screen to the following Item...

Страница 55: ...en not using language switching the settings are not required Please refer to 5 4 Comment for language switching Item Setting Use Language Switching Checked Language Switching Device Com_Label s16_Com...

Страница 56: ...ting System Information to open the setting screen and set the following items When not using the reset switch of system alarms the settings are not required Please refer to 5 1 22 System Alarm GOT B...

Страница 57: ...50 Turns ON the station number switching flag else When the value in the screen switching device is for other than sample screens switches the station number switching device to the host station if Co...

Страница 58: ...meter List Screen How to change the settings is explained below with the example of displaying Pr 165 Stall prevention operation level for restart in Parameter List screen 1 Go to Common Recipe and se...

Страница 59: ...e set which is the maximum number When the set devices are less than 200 make sure to set 9999 to the final No 5 Click OK Precautions Do not register calibration parameters Pr 900 to Pr 935 Regarding...

Страница 60: ...lish INVERTER FR E800 Instruction Manual Function English 12001 Japanese INVERTER FR E800 Instruction Manual Function Japanese 12002 Chinese Simplified INVERTER FR E800 Instruction Manual Function Chi...

Страница 61: ...al Function and INVERTER FR E800 Instruction Manual Maintenance at the creation of this sample screen please refer to the table below INVERTER FR E800 Instruction Manual Function English Japanese Chin...

Страница 62: ...of 2 Protective Functions in the English manual Japanese Manual Change the constant of word set Com_Label u16_Com_DocPageNum from 45 to the page number of 3 Parameters in the Japanese manual Change t...

Страница 63: ...LECTRIC Controller Type FREQROL 800 E700NE Batch monitor I F Standard I F RS422 RS485 2 Detail Setting Item Set Value Remarks Transmission Speed BPS 115200 Data Bit 8bit Stop Bit 1bit Parity Odd Retry...

Страница 64: ...ing time setting Pr 123 5 1 PU communication CR LF selection Pr 124 1 Default value Protocol selection Pr 549 0 Default value Operation mode selection Pr 79 0 Default value Communication startup mode...

Страница 65: ...comment No is 1 Therefore the comment No obtained by the value of station number 1 is required to be referred Example Change the settings of the object which displays the axis name in Parameter List...

Страница 66: ...ernet interface unit is as below 1 For the FR E800 E inverter System Configuration 1 For more details on the cable please refer to GOT2000 Series Connection Manual Mitsubishi Products Ethernet cable 1...

Страница 67: ...ec 3 Delay Time ms 0 3 GOT Ethernet Setting Item Set Value Remarks Update GOT Ethernet Standard Port Setting Checked GOT IP Address 192 168 3 18 Subnet Mask 255 255 255 0 Default Gateway 0 0 0 0 Perip...

Страница 68: ...ttings Network Station No IP Information and set the destination network number station number and IP address after setting Table Conversion System to Setting System 1 Item Set Value Remarks Setting S...

Страница 69: ...2 Pr 1435 Ethernet IP address 3 Pr 1436 Ethernet IP address 4 Pr 1437 Subnet mask 1 Pr 1438 255 Default value 1 2 Subnet mask 2 Pr 1439 255 Default value 1 2 Subnet mask 3 Pr 1440 255 Default value 1...

Страница 70: ...IE TSN limits the operation of the operation command screens and Machine Diagnosis Load Characteristics Measurement screen For details please refer to 8 Limitations System Configuration 1 For more det...

Страница 71: ...n Port No 5015 Transparent Port No 5014 4 Connected Ethernet Controller Setting Host Net No Station Unit Type IP Address Port No Communication 1 1 1 RCPU 192 168 3 39 5006 UDP 5 Routing Information Se...

Страница 72: ...n Station Number Switching In this sample screen station No can be switched between 1 and 16 in the default setting When switching to the number other than 1 to 16 such as station number 17 please ref...

Страница 73: ...r than the CH1 change the settings as below Setting Example When connecting the inverter to CH2 1 Open Station No Switching in the Controller Setting tree and check the CH that is being connected to t...

Страница 74: ...the same network number and station number that have been changed in 1 1 Enter the new network number and station number 1 The structure of the value stored in the station number switching device is...

Страница 75: ...to Search Replace Batch Edit and select Network and make changes from the Network Batch Edit dialog a Select Project under Target b Click Find Now c Select 1 1 and click displayed d Input the network...

Страница 76: ...nge the Recipe No under the Basic tab otherwise the parameter recipe will not work properly 3 Change the comment of each switch in the B 14000 Station Number Switching screen Change the comments for t...

Страница 77: ...0 Change the link devices RX RY RWw RWr of the master station to control the link devices RX RY RWw RWr value The screens below have the limitations in this sample screen Screen Limitations B 12120 B...

Страница 78: ...wise the recipe setting of this sample screen does not operate correctly 9 3 When the SD Card or the SRAM User Area of the GOT Does Not Have the Sufficient Available Space Recipe function is used in t...

Страница 79: ...CC Link IE are trademarks or registered trademarks of Mitsubishi Electric Corporation in Japan and other countries Ethernet is a registered trademark of Xerox Corporation in the United States Other c...

Отзывы: