4. Inverter FR-E800-E
4.1 Inverter FR-E800-E Communication Settings
Set the parameters of communication settings with PU (operation panel or parameter unit). An inverter reset after
the setting is required for the parameters of the communication settings.
Item
Parameter
Set value
Remarks
Operation mode selection
Pr.79
0
(Default value)
*2
Communication startup mode
selection
Pr.340
10
(Default value)
*2
Communication EEPROM write
selection
Pr.342
0
(Default value)
*2
PLC function operation selection
Pr.414
0
(Default value)
*2 *3
Stop mode selection at
communication error
Pr.502
0
(Default value)
*2
Protocol selection
Pr.549
0
(Default value)
NET mode operation command
source selection
Pr.550
5
*2
Operation frequency during
communication error
Pr.779
9999
(Default value)
*2
Ethernet communication network
number
Pr.1424
1 to 239
*1
Ethernet communication station
number
Pr.1425
1 to 120
*1
Link speed and duplex mode
selection
Pr.1426
0
(Default value)
*2
Ethernet function selection 1
Pr.1427
5000 to 5002,
5006 to 5008
*1
Ethernet function selection 2
Pr.1428
9999
*2
Ethernet function selection 3
Pr.1429
9999
*2
Ethernet signal loss detection
function selection
Pr.1431
0
*2
Ethernet communication check
time interval
Pr.1432
9999
*2
Ethernet IP address 1
Pr.1434
0 to 255
*1
Ethernet IP address 2
Pr.1435
*1
Ethernet IP address 3
Pr.1436
*1
Ethernet IP address 4
Pr.1437
*1
Subnet mask 1
Pr.1438
255
(Default value)
*1 *2
Subnet mask 2
Pr.1439
255
(Default value)
*1 *2
Subnet mask 3
Pr.1440
255
(Default value)
*1 *2
Subnet mask 4
Pr.1441
0
(Default value)
*1 *2
*1: Settings of the GOT can be changed. When changing the settings, also change the settings of the inverter.
*2: Change the settings depending on the operation environment.
*3: Because the default value of the inverter is "0: disabled", change the value to 1 or 2 when using PLC function.
[Additional Explanation]
When trying to monitor the devices of the PLC such as X and Y at the time when Pr.414 "PLC function operation
selection" is "0: disabled", the system alarm "322 Dedicated device is out of range. Confirm
device range." is output.