5.1.20 Logging (B-14900)
Outline
This is the screen part that the device can be displayed as a historical trend graph by setting the device of the
inverter to monitor by user.
Description
1. Displays the data collected by logging as a historical trend graph.
2. Operates the historical trend graph.
: Switches the displayed page of the historical trend graph.
: Scrolls the historical trend graph.
: Moves the cursor displayed in the historical trend graph.
: Enlarges/reduces the time axis of the historical trend graph.
: Updates the historical trend graph.
3. Displays the end position time of the waveform displayed in the historical trend graph.
4. Displays the current value of the monitor device of the target device and the information of the cursor
position when the cursor is displayed in the historical trend graph.
5. Displays the beginning position time of the waveform displayed in the historical trend graph.
Remarks
・
[Go To Screen] switch to [Logging] screen is not placed.
[Go To Screen] switch to [Logging] screen needs to be created by the user.
・
The target device of the logging is the device set to "flt_Logging_dev" of the label group No.121
"INV_E800_Label" in label (GT Designer 3). Because "GD19990" is set in the default setting, change the
device to the device of the inverter to perform the logging.
・
This screen is excluded from the target of station number switching. For the details of the station No.
switching function, please refer to "GT Designer3 (GOT2000) Screen Design Manual".
・
Logging trigger cannot be operated in the default setting. Therefore change the settings of the logging
trigger according to the timing to perform logging.
1
3
5
4
2