![Mitsubishi FR-E 500 Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/mitsubishi/fr-e-500/fr-e-500_installation-manual_1809259021.webp)
FR-E 500 EC
21
Parameter
Func-
tion
Para-
meter
Meaning
Setting range
Default
Second
functions
44
Second acceleration/deceleration time
0–360s / 0–3600s
5s / 10s
45
Second deceleration time
0–360s / 0–3600s /
9999
9999
46
Second torque boost
0–30% / 9999
9999
47
Second V/F (base frequency)
0–400Hz / 9999
9999
48
Second stall prevention operation current
0–500A / 9999
9999
Display
functions
52
Control panel/PU main display data selection
0 / 23 / 100
0
55
Frequency monitoring reference
0–400Hz
50Hz
56
Current monitoring reference
0–500A
Rated current
Automatic
restart
functions
57
Restart coasting time
0–5 s / 9999
9999
58
Restart cushion time
0–60s
1s
Additional
function
59
Remote setting function selection
0 / 1 / 2
0
Operation
selection
functions
60
Shortest acceleration/ deceleration mode
0 / 1 / 2 / 11 / 12
0
61
Reference current
0–500A / 9999
9999
62
Reference current for acceleration
0–200% / 9999
9999
63
Reference current for deceleration
0–200% / 9999
9999
65
Retry selection
0 / 1 / 2 / 3
0
66
Stall prevention operation level
reduction starting frequency
0–400Hz
50Hz
67
Number of retries at alarm occurrence
0–10 / 101–110
0
68
Retry waiting time
0.1–360s
1s
69
Retry count display erasure
0
0
70
Special regenerative brake duty
0–30%
0%
71
Applied motor
0/1/3/5/6/13/15/16/
100/101/103/105/106/
113/115/116
0
72
PWM frequency selection
0–15
1
73
0–5V / 0–10V selection
0 / 1 / 10 / 11
0
74
Filter time constant
0–8
1
75
Reset selection / disconnected PU detection /
PU stop selection
0–3 / 14–17
14
77
Parameter write disable selection
0 / 1 / 2
0
78
Reverse rotation prevention selection
0 / 1 / 2
0
79
Operation mode selection
0–4 / 6–8
0
Motor
constants
80
Motor capacity
0.2–7.5kW / 9999
9999
82
Motor exciting current
0–500A / 9999
9999
83
Rated motor voltage
0–1000V
200V / 400V
84
Rated motor frequency
50–120Hz
50Hz
90
Motor constant A
0–50
Ω
/ 9999
9999
96
Auto-tuning setting / status
0 / 1
0
Communi-
cation
functions
117
Station number
0–31
0
118
Communication speed
48 / 96 / 192
192
119
Stop bit length / data length
0 / 1 / 100 / 101
Datenlänge 8
10 / 11 / 110 / 111
Datenlänge 7
1
120
Parity check presence / absence
0 / 1 / 2
2
121
Number of communication retries
0–10 / 9999
1
122
Communication check time interval
0–999.8s / 9999
9999
123
Waiting time setting
0–150ms / 9999
9999
124
CR / LF presence/absence selection
0 / 1 / 2
1