76
-
Note (1) The number of flashes when in the Service Mode do not include the 1.5 second period when the lights light up at first (starting signal). (See the example
shown below.)
0.5 sec.
1.5 sec.
RUN light
(10’
s digit)
TIMER light
(1’
s digit)
11-second interval
0.5 sec.
OFF
ON
OFF
ON
Notes
(2) Error display:
-
Is not displayed. (automatic recovery only)
◦
Displayed.
If there is a ( ) displayed, the error display shows the number of times that an auto recovery occurred for the same reason has
reached the number of times in ( ).
If no ( ) is displayed, the error display shows that the trouble has occurred once.
Notes
(3) Auto Recovery:
- Does not occur
◦
Auto recovery occurs.
(d) Remote controller information tables
1) Operation switching
RUN light
(Operation switching)
Display pattern when
in service mode
Operation switching
when there is an
abnormal stop
0
1
2
4
3
AU
TO
DR
Y
COOL
FAN
HEAT
2) Fan speed switching
TIMER light
(Fan speed switching)
Display pattern when
in service mode
Fan speed
switching when
there is an
abnormal stop
0
2
3
4
6
7
AU
TO
HI
MED
LO
HI POWER
ECONO
* If no data are recorded (error code is normal), the information display in the remote controller becomes as follows.
Remote controller setting
Operation switching
Fan speed switching
Display when error code is normal.
AU
TO
AU
TO
0.5 sec.
1.5 sec.
RUN light
(10’
s digit)
TIMER light
(1’
s digit)
11-second interval
0.5 sec.
OFF
ON
OFF
ON
(Example): Operation switching, fan speed switching, cooling HI