Chapter 8
PERIODIC INSPECTION AND MAINTENANCE PROCEDURES
8-11
Refilling the coolant
1.
Make sure drain cocks and plugs are closed tightly.
2.
Remove the radiator cap, and pour in undiluted
LLC.
Note:
Determine the amounts of LLC and water to be
added by using the LLC concentration chart. For
coolant, refer to
"COOLANT" (6-1)
.
For coolant capacity, refer to
"MAIN SPECIFI-
CATIONS" (12-1)
.
3.
Pour in water (soft water with minimal impurities,
such as tap water) slowly to the full level.
4.
Check the radiator and other parts for coolant
leaks. If a coolant leak is found, repair it.
5.
When coolant reaches the full level, close the radi-
ator cap securely.
6.
Shut off the fuel supply and crank the engine for
about 10 seconds or less using the starter. Wait for
about 1 minute, then repeat the above cranking
operation to remove air from the water pump.
&$87,21
To crank the engine, shut off the fuel supply to the
engine and operate the starters.
7.
Check the coolant level in the radiator. If the
engine is equipped with a reserve tank, fill the
reserve tank with coolant to the full level as well.
&$87,21
When adding coolant, use a coolant that has the same
LLC concentration as the coolant already in the radia-
tor.
Fig. 8-18
Radiator
Fig. 8-19
Reserve tank