28
Electrical installation
Cable lock
Use a suitable tool to release/lock cables in the terminal block.
HSB60-W, RC-HY20/40-W
Terminal block on the electrical card
2
1
2
3
LEK
3
4
1
2
1
2
Terminal block
LEK
1 mm
3,5 mm
Connection for HSB60-W
NOTE
To prevent interference, unscreened communication and/
or sensor cables to external connections must not be laid
closer than 20 cm from high voltage cables.
Power supply
Indoor unit
In case of HSB60, power supply is made to indoor unit,
outdoor unit and controller separately. 230V 1AC 50Hz is
applied.
For indoor unit, incoming supply is connected on AA23-X1
terminal.
AA23-X1
AA23-F3
AA23
AA23-X4
AA23-S3
AA23-X100
For outdoor unit, incoming supply is connected on TB
WHUPLQDO6HH¿JXUHRQ&RQQHFWLRQEHWZHHQLQGRRUDQGRXWGRRU
unit.
Controller
Connection between indoor and outdoor unit
The communication cable between indoor and outdoor unit is
connected between terminal AA23-X100 in indoor unit and TB
in outdoor unit. Screened 2 core cable is recommended.
AA23-X100
1
2
3
4
L
1
3 (AMS 10:TB)
N
2
Central
FDCW 60
HSB 60
AA23-X100
TB
Electrical distribution
unit
Yellow/
Green
Brown Blue
Communication
Communication
Содержание FDCW60VNX-W
Страница 2: ......
Страница 77: ...75 Technical data Electrical circuit diagram HSB60 W ...
Страница 78: ...76 Technical data HMK60 RC HY FDCW60VNX A FDCW60VNX A 2 FDCW60VNX A 3 ...
Страница 79: ...77 Technical data FDCW60VNX A 2 FDCW60VNX A 3 RC HY RC HY RC HY ...
Страница 80: ...78 Technical data RC HY RC HY RC HY ...
Страница 83: ...81 Technical data sheet 3 ...
Страница 84: ...82 Technical data sheet 4 ...
Страница 87: ...85 Technical data sheet 3 ...
Страница 88: ...86 Technical data sheet 4 ...
Страница 89: ...87 Technical data INDOOR UNIT HSB INDOOR UNIT HSB sheet 5 ...
Страница 90: ...88 Technical data sheet 6 ...
Страница 91: ...89 MEMO ...