34
Electrical installation
Step controlled additional heat
NOTE
Mark up any junction boxes with warnings for
external voltage.
External step controlled additional heat can be controlled by up
to three potential-free relays in the control module (3 step
linear or 7 step binary). Alternatively two relays (2 step linear
or 3 step binary) can be used for step controlled additional
heat, which means that the third relay can be used to control
the immersion heater in the water heater/accumulator tank.
Step in occurs with at least 1 minute intervals and step outs
with at least 3 seconds intervals.
6WHSLVFRQQHFWHGWRWHUPLQDOEORFN;RQWKHDGGLWLRQDO
relay board (AA7).
6WHSLVFRQQHFWHGWRWHUPLQDOEORFN;RQWKHDGGLWLRQDO
relay board (AA7).
Step 3 or immersion heater in the water heater/accumulator
WDQNLVFRQQHFWHGWRWHUPLQDOEORFN;RQWKHDGGLWLRQDO
relay board (AA7).
The settings for step controlled additional heat are made in
menu 4.9.3 and menu 5.1.12.
All additional heat can be blocked by connecting a potential-
free switch function to the software controlled input on
terminal block X2 which is selected in menu 5.4.
SMO
E
6
1
0
PE
A1
A2
A1
A2
A1
-K1
-K2
-K3
A2
External
RC-HY
20/40
AA7-X2
X1
LEK
L N
1
1
0
2 3 4
PE
X1
1
1
N
L
0
E
P
2 3 4
-X2
1
12
34
56
2 3 4 5 6
-X1
AA7-X2
RC-HY20/40
If the relays are to be used for control voltage, bridge the
VXSSO\IURPWHUPLQDOEORFN;WR;;DQG;RQ
additional relay board (AA7). Connect the neutral from the
H[WHUQDODGGLWLRQDOKHDWWRWHUPLQDOEORFN;
Use a cable with appropriate cross section.
For connection, see the installation manual for additional
heater.
Optional connections
RC-HY20
Room sensor BT50
Room sensor can be connected to controller.
7KHURRPWHPSHUDWXUHVHQVRUKDVXSWRWKUHHIXQFWLRQV
1. Show current room temperature in the control module
display.
2. Option of changing the room temperature in °C.
3. Makes it possible to change/stabilise the room temperature.
Install the sensor in a neutral position where the set temperature
is required. A suitable location is on a free inner wall in a hall
DSSUR[PDERYHWKHÀRRU
Do not install the sensor where correct room temperature
cannot be detected such as in a recess, between shelves, behind
a curtain, above or close to a heat source, in a draft from an
external door or in direct sunlight.
Closed radiator thermostats can also cause problems.
The control module can operate without the sensor, but if user
ZDQWVWRUHDGR൵WKHDFFRPPRGDWLRQVLQGRRUWHPSHUDWXUHLQ
controller display, the sensor must be installed.
Connect the room sensor to the port 7 and 10 on X2 terminal.
If the sensor is to be used to change the room temperature in
°C and/or to change/stabilise the room temperature, the sensor
must be activated in menu 1.9.4.
,IWKHURRPVHQVRULVXVHGLQDURRPZLWKXQGHUÀRRUKHDWLQJLW
should only have an indicatory function, not control of the
room temperature.
9
10
11
6
8
7
External
RC-HY 20
X2
BT50
RC-HY20
X2
CAUTION
Changes of temperature in accommodation
take time. For example, short time periods in
combination with underfloor heating will not
give a noticeable difference in room temperature.
Use two-core cable with a minimum 0.5mm
2
cross section.
Содержание FDCW60VNX-W
Страница 2: ......
Страница 77: ...75 Technical data Electrical circuit diagram HSB60 W ...
Страница 78: ...76 Technical data HMK60 RC HY FDCW60VNX A FDCW60VNX A 2 FDCW60VNX A 3 ...
Страница 79: ...77 Technical data FDCW60VNX A 2 FDCW60VNX A 3 RC HY RC HY RC HY ...
Страница 80: ...78 Technical data RC HY RC HY RC HY ...
Страница 83: ...81 Technical data sheet 3 ...
Страница 84: ...82 Technical data sheet 4 ...
Страница 87: ...85 Technical data sheet 3 ...
Страница 88: ...86 Technical data sheet 4 ...
Страница 89: ...87 Technical data INDOOR UNIT HSB INDOOR UNIT HSB sheet 5 ...
Страница 90: ...88 Technical data sheet 6 ...
Страница 91: ...89 MEMO ...