41
Commissioning and adjusting
Start-up and inspection
Before start-up
1
In case of cascade connection, check if each indoor unit has
a unique address. See Cascade connection setting on page
29 for details.
2. For an outdoor unit equipped with a crank case heater, it is
necessary to supply power 6-8 hours before starting
compressor operation to heat the compressor with the heater.
To do this, supply power to whole system and disable the
compressor operation from menu 5.2.2 on the controller.
Disable additional heater as well if necessary.
3. After 6-8 hours, enable the compressor operation in menu
5.2.2 on the controller and enable the additional heater in
menu 4.9.2 and 4.9.3 on the controller.
4. Start commissioning by the following steps.
*Step 2 and 3 are not necessary for FDCW60VNX-W.
Commissioning with heat pump
Start guide is shown on the display on the controller when it is
turned ON for the first time. Follow the start guide in the
display, or choose menu 5.7 to show the start guide. For details,
see Start guide on page 42.
Commissioning with additional heater
only
Follow the start guide in the display as same as commissioning
with heat pump, and then follow the list below.
1. Go to menu 4.2 op. mode.
0DUN´DGGKHDWRQO\´XVLQJWKHFRQWURONQREDQGWKHQSUHVV
the OK button.
3. Return to the main menus by pressing the Back button.
CAUTION
When commissioning without MHI air/water heat pump an
alarm communication error may appear in the display.
The alarm is reset if the relevant heat pump is deactivated
in menu 5.2.2 ("installed heat pump").
3-way valve operation check
1. Activate "AA2-K1 (QN10)" in menu 5.6.
2. Check that the reversing valve opens or is open for hot water
charging.
3. Deactivate "AA2-K1 (QN10)" in menu 5.6.
AUX function check
To check any function connected to the AUX socket,
$FWLYDWH³$$;5&+<´RU³$$;5&+<´
in menu 5.6.
2. Check the desired function.
'HDFWLYDWH ³$$; 5&+<´ RU ³$$; 5&
+<´LQPHQX
Cooling mode
In case the climate system contains a cooling circuit, activate
cooling function in menu 5.11.1.1. After that, you can choose
cooling mode indication in menu 5.4 for the AUX output.
Cleaning particle filter
&OHDQWKHSDUWLFOH¿OWHU+4DIWHULQVWDOODWLRQ
&ORVHYDOYH40DQGWKHYDOYHE\WKHSDUWLFOH¿OWHU+4
2.
Open the safety valve (QM20) to ensure that the pressure in
HSB60 drops.
&OHDQWKHSDUWLFOH¿OWHU+4DVLOOXVWUDWHG
LEK
LEK
1
2
Secondary adjustment
Air is initially released from the hot water and venting may be
necessary. If bubbling sounds can be heard from the heat pump,
the circulation pump and radiators the entire system will
require further venting. When the system is stable (correct
pressure and all air eliminated) the automatic heating control
system can be set as required
Содержание FDCW60VNX-W
Страница 2: ......
Страница 77: ...75 Technical data Electrical circuit diagram HSB60 W ...
Страница 78: ...76 Technical data HMK60 RC HY FDCW60VNX A FDCW60VNX A 2 FDCW60VNX A 3 ...
Страница 79: ...77 Technical data FDCW60VNX A 2 FDCW60VNX A 3 RC HY RC HY RC HY ...
Страница 80: ...78 Technical data RC HY RC HY RC HY ...
Страница 83: ...81 Technical data sheet 3 ...
Страница 84: ...82 Technical data sheet 4 ...
Страница 87: ...85 Technical data sheet 3 ...
Страница 88: ...86 Technical data sheet 4 ...
Страница 89: ...87 Technical data INDOOR UNIT HSB INDOOR UNIT HSB sheet 5 ...
Страница 90: ...88 Technical data sheet 6 ...
Страница 91: ...89 MEMO ...