−29−
−28−
High power operation
The high power operation adjusts the room temperature quickly to a pleasant level by increasing the operation capacity.
The high power operation continues for 15 minutes at the maximum and returns to the normal operation automatically. When the operation mode is changed, the high power
operation returns to the normal operation, too.
High power operation must be set to the
F1
or F2 switch.
High power operation is set to the
F1
switch as the factory setting.
1
Push the
F1
( F2 ) switch to start the high power operation.
■
Operation will start when the
F1
(
F2
) switch is pushed, even if
Run/Stop
switch is off.
■
High power operation is only allowed when Heating or Cooling is selected for the operation mode.
Message “In operation for high power.” is displayed on the R/C screen, and “—, —°C” is displayed on the Set temp button
during the high power operation.
■
Set temp and change fan speed operations are disabled during high power operation.
2
High power operation is terminated when you perform one of the following.
・
When you terminate through a Run/Stop operation
・
When you change the operation mode
・
When15 minutes have elapsed since the high power operation started
・
When you terminate the high power operation with the
F1
( F2 ) switch
Menu
Direction
Cooling
15
:
50
(Mon)
F1: High power
Timer
In operation for high power.
Set temp
F2: Energy-saving
1
Push the
F1
( F2 )switch to start the energy-saving operation.
■
Operation will start even if you press the
F1
(
F2
) switch while the unit is stopped.
■
Energy-saving operation is only allowed when Heating, Cooling or Auto is selected for the operation mode.
Message “In operation for energy-saving.” is displayed on the screen during the energy-saving operation. Set temp is fixed at
“28.0°C” in the cooling operation or “22.0°C” in the heating operation. Set temp shows “- -°C” in the automatic operation mode.
■
Set temp cannot be changed during the energy-saving operation. If it is attempted, a message “Invalid request” is displayed on the screen.
2
Energy-saving operation is terminated when you perform the following.
・
When you terminate through a Run/Stop operation
・
When you change the operation mode
・
When you terminate the energy-saving operation with the
F1
( F2 ) switch
Energy-saving operation
Use this operation to save energy. Set temp is fixed at 28°
C in the cooling operation or 22
°
C in the heating operation. Since the capacity is controlled automatically based on the
outdoor temperature, energy can be saved without losing comfort.
Energy-saving operation must be set to the
F1
or F2 switch.
Energy-saving operation is set to the F2 switch as the factory setting.
Menu
Direction
Auto
16
:
04
(Mon)
F1: High power
F2: Energy-saving
Timer
In operation for energy-saving.
Set temp
PJZ012A172_EN.indd 28