Anti Rolling Gyro
Model:MSM-37500T-A1
−
28
−
Table 6-1
ARG
Periodic inspection List
(
2 / 4
)
No
Inspection
Area
Inspection Item
Priority
Result
Countermeasures
5
ARG
installation
There must be
enough ventilation
provided to cool the
ARG
down.
○
Improve installation
environment.
6
The
ARG
unit must
be no rust, crack or
damage caused by
interference of the
ARG
unit and other
equipment.
○
Contact the Sales
Agent.
Change the
damaged parts or
the
ARG
unit.
7
There must be no
trace of being
exposed to seawater
/ water on the
ARG
unit.
◎
Contact the Sales
Agent.
(Do not operate the
ARG
.)
8
The blowhole of the
ARG
unit must not be
closed.
○
9
There must be no
objects on the
ARG
cover.
○
Improve the
ARG
unit to solve the
problem.
10
There must be no
looseness in the
screws of the Cover.
○
Re-tighten screws
with glue.
Tighten Torque
2.6 to 2.8N
・
m
And contact the
Sales Agent.
11
ARG
unit
There must be no
looseness in the bolts
of the Damper.
◎
Contact the Sales
Agent.
Inspect the
ARG
and, change
damaged parts.