Anti Rolling Gyro
Model:MSM-37500T-A1
−
19
−
4.2 Restarting
Please operate the
ARG
according to the procedure below if the
ARG
is restarted
due to any kind of anomalies.
*1) It takes approximately 1 hour until the
ARG
completely stops after the remote
switch has been turned off. If you turn on the switch back before the
ARG
unit
has stopped completely, self-shutdown circuit may occur due to over current.
In this case, release the over current of the Motor Driver and then restart the
ARG
. It will be better not to restart the
ARG
for at least 1 hour after shutdown.
*2) If number of the Monitoring window is same as shown in Table 4-1,
the
ARG
is normal.
*3) The
ARG
takes approximately 45 minutes to reach rated rotational speed
after turning on the remote switch.
④
“Turn OFF” the circuit breaker switch.
①
“Turn OFF” the remote switch.
②
Make sure that the start check lamp is “OFF”.
③
Make sure that the rotation rate check lamp is “OFF”.
⑥
“Turn ON” the circuit breaker switch.
*1
⑦
“Turn ON” the remote switch.
*2
⑧
Make sure that the start check lamp is “ON”.
<
45 minutes later
*3
>
⑨
Make sure that the rotation rate check lamp is “ON”.
⑩
Make sure that there is no unusual noise and vibration during
the
ARG
operation.
⑪
If the test run is performed on the sea, anti-rolling function
becomes effective in approximately 45 minutes after starting.
⑤
Make sure that the
ARG
is stopping completely 1 hour later.