12
no
9. Spesifikasjoner
9.1. Utendørsenhet spesifikasjoner
Utendørsmodell
SUZ-SWM40
SUZ-SWM60
SUZ-SWM80
Strømforsyning
V / Fase / Hz
230 / Enkel / 50
Størrelse (B × H × D)
mm
840 × 880 × 330
Lydnivå *1 (Varme)
dB(A)
57
59
61
*1. Målt under nominell driftsfrekvens.
9.2. Tilgjengelig område (vannstrømningshastighet, returvannstemp.)
Følgende vannstrømningshastighet og returtemperaturområde er nødvendig i vannkretsen.
5,0
7,0
9,0
11,0
13,0
15,0
17,0
19,0
6,0
7,0
8,0
9,0
10,0
11,0
12,0
13,0
returvannstemp.
[
℃
]
vannstrømningshastighet [
ℓ
/min]
SUZ- SWM40VA
tilgjengelig område
5,0
7,0
9,0
11,0
13,0
15,0
17,0
19,0
6,0
8,0
10,0
12,0
14,0
16,0
18,0
returvannstemp.
[
℃
]
vannstrømningshastighet [
ℓ
/min]
SUZ- SWM60VA
tilgjengelig område
5,0
7,0
9,0
11,0
13,0
15,0
17,0
19,0
7,0
9,0
11,0
13,0
15,0
17,0
19,0
21,0
23,0
returvannstemp.
[
℃
]
vannstrømningshastighet [
ℓ
/min]
SUZ- SWM80VA
tilgjengelig område
Sørg for å utføre frostbekyttelsesforanstaltning som f.eks. å bruke frostvæske når du bruker enheten i kjølemodus under lav omgivelsestemperatur (under 0 °C).