12
it
9. Specifiche
9.1. Specifiche unità esterna
Modello esterno
SUZ-SWM40
SUZ-SWM60
SUZ-SWM80
Alimentazione
V / fase / Hz
230 / singola/ 50
Dimensioni (L × A × P)
mm
840 × 880 × 330
Livello acustico *1 (riscaldamento)
dB(A)
57
59
61
*1. Misurate con frequenza operativa nominale.
9.2. Intervallo disponibile (portata acqua, temp. acqua di ritorno).
Il circuito dell'acqua deve avere la portata dell'acqua e la temperatura dell'acqua di ritorno seguenti.
5,0
7,0
9,0
11,0
13,0
15,0
17,0
19,0
6,0
7,0
8,0
9,0
10,0
11,0
12,0
13,0
Temp. acqua di ritorno
[
℃
]
Portata acqua [
ℓ
/min]
SUZ- SWM40VA
Intervallo disponibile
5,0
7,0
9,0
11,0
13,0
15,0
17,0
19,0
6,0
8,0
10,0
12,0
14,0
16,0
18,0
Temp. acqua di ritorno
[
℃
]
Portata acqua [
ℓ
/min]
SUZ- SWM60VA
Intervallo disponibile
5,0
7,0
9,0
11,0
13,0
15,0
17,0
19,0
7,0
9,0
11,0
13,0
15,0
17,0
19,0
21,0
23,0
Temp. acqua di ritorno
[
℃
]
Portata acqua [
ℓ
/min]
SUZ- SWM80VA
Intervallo disponibile
Provvedere alla protezione antigelo applicando ad esempio una soluzione antigelo in caso di attivazione dell'unità in modalità di raffreddamento con temperatura ambiente
bassa (sotto 0°C).