46
2 EQUIPMENT SPECIFICATIONS
2.4 SSCNETIII Cables
■
When using communication type "SSCNET
"
Set the axis No. for the station No. (d01 to d16) of each servo amplifier set on each line.
The station No. (d01 to d16) of servo amplifier on the servo network setting screen corresponds to axis select rotary switch (0
to F) of servo amplifier.
The table for setting the station No. and the axis select rotary switch of the servo amplifier is shown in the table below.
*1 When using MR-J4(W)-
B, turn the auxiliary axis No. setting switches to OFF.
Connector No. of Motion CPU module
Correspondence between SSCNET
(/H) line and connector No. of Motion CPU module is shown in the table below.
*1 Number of SSCNET
(/H) lines: R64MTCPU/R32MTCPU: 2 lines/R16MTCPU: 1 line
The setting of axis select rotary switch and auxiliary axis No. setting switches differs depending on the servo
amplifier.
Refer to the following for details.
Servo amplifier Instruction Manual
Axis select rotary switch
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
d01
d02
d03
d04
d05
d06
d07
d08
d09
d10
d11
d12
d13
d14
d15
d16
SSCNETIII(/H) line No.
Connector No. of Motion CPU
1
CN1
2
CN2
Axis select rotary switch
8
0
7
F
6
E
5
D
4
C
3
B
2
A
1
9
Set the Axis No. and Station No.