2 EQUIPMENT SPECIFICATIONS
2.2 Motion CPU Module
39
2
Specifications
This section describes the Motion CPU specifications.
Module specifications
*1 Servo amplifiers for SSCNET cannot be used.
*2 SSCNET
and SSCNET
/H cannot be combined within the same line. For R64MTCPU/R32MTCPU, SSCNET
and SSCNET
/H
can be set for each line.
*3 When using the optical hub unit, the maximum combined cable length depends on the system configuration.
*4 For half-duplex transmission, response time may be longer depending on the external device. When connecting with an external device
via a switching HUB, set to full-duplex transmission.
Item
R64MTCPU
R32MTCPU
R16MTCPU
Number of control axes
Up to 64 axes
Up to 32 axes
Up to 16 axes
SSCNET communication
Communication type
SSCNET
/H, SSCNET
Number of lines
2 lines
1 line
Distance between stations
(maximum) [m(ft.)]
SSCNET
/H
100(328.08)
SSCNET
50(164.04)
Combined cable length
(maximum) [m(ft.)]
SSCNET
/H
3200(10498.69)
1600(5249.34)
SSCNET
800(2624.67)
Number of sensing module connection
stations
Up to 8 stations (Up to 4 stations/line)
Up to 4 stations
Number of SSCNET
/H head module
connection stations
Number of optical hub unit connections
Up to 32 units (Up to 16 units/line)
Up to 16 units
PERIPHERAL I/F
(Ethernet)
Data transmission speed
100Mbps/10Mbps
Communication mode
Transmission method
Base band
Cable length (maximum) [m(ft.)]
30(98.43)
Memory card slot
SD/SDHC memory card compatible
Memory capacity
Standard ROM
12M bytes
SD memory card
Memory card capacity (Up to 32G bytes)
Number of stages of extension base
Up to 7 stages
Internal current consumption (5VDC) [A]
1.20
Mass [kg]
0.28
Exterior dimensions [mm(inch)]
106.0(4.17)(H)
27.8(1.09)(W)
110.0(4.33)(D)
Содержание R16MTCPU
Страница 1: ...MELSEC iQ R Motion Controller User s Manual R16MTCPU R32MTCPU R64MTCPU ...
Страница 2: ......
Страница 89: ......