S1 S2 S3
Terminal block cover
When removing:
When attaching:
Clamp 1
Cylinder unit /
outdoor unit
connecting cables
Pipe sleeve end
alignment mark
Clamp 2
Pipe sleeve
B pipe
Notes
1
Remove the piping cover and terminal block cover.
• Remove the piping cover followed by the terminal block cover, in that order.
2
Pass the cylinder unit / outdoor unit connecting cables from the cylinder
unit to the outdoor unit through a pipe sleeve (16 mm diameter).
• Cylinder unit / outdoor unit connecting cables shall not be lighter than
polychloroprene sheathed flexible cable.
(Design 60245 IEC 57)
3
Secure the cylinder unit / outdoor unit connecting cables in place using
clamp 1.
• Secure firmly in place while being careful that no external force is applied
directly to the terminal section.
4
Secure the pipe sleeve using clamp 2 (2 locations).
• At factory shipping, the drain socket is secured to clamp 2, and so carefully
remove the drain socket, and secure the pipe sleeve.
• To prevent the entry of water into the pipe sleeve, wrap
tape around the pipe sleeve end, align the pipe sleeve
end with the alignment mark, and put it inside the
terminal block cover.
• Secure so that the pipe sleeve does not contact the B pipe.
(The B pipe can reach temperatures of 72°C or higher.)
5
Connect the cylinder unit / outdoor unit connecting cables to the outdoor
unit terminal block of the outdoor unit.
• The terminals have polarity, so be sure to match the terminal number when
connecting the cables.
• Pull each wire one at a time to check that they are not disconnected.
6
After the wire routing is completed, attach the terminal block cover and
piping cover.
• Attach the terminal block cover followed by the piping cover, in that order.
cylinder unit /
outdoor unit
connecting
cables
Pipe
sleeve
Tape
4
en
TB2
S1
S2
S3
S1
S2
S3
TB
Fig. 6-1
Fig. 6-2
6. Electrical work
Outdoor unit
Cylinder unit
Isolating
switch
Terminal block for outdoor unit
(This terminal has polarity.)
Align the pipe sleeve
end with the mark.
Pipe sleeve end
alignment mark
Pipe sleeve for cylinder unit /
outdoor unit connecting cables
Cylinder unit / outdoor unit
connecting cables from
cylinder unit
Connection method for cylinder unit / outdoor unit connecting
cables
(Fig. 6-2)
Piping cover
Outdoor unit powered via cylinder unit
(Fig. 6-1)
5
3
2
4
2
1
1
Содержание QUHZ-W40VA