4
- 15
4.5 Intelligent Function Module Switch Setting
4
PROCEDURES AND SETTINGS BEFORE
OPERATION
(Example) Target channel: channel 1, pulse input mode setting: 1 multiple of 2
phases, counting speed setting: 200 kPPS, counter format: ring counter, and present
value selection setting: setting value B
Set the switch 1 0003
H
.
Set the switch 3 0002
H
.
Set the switch 4 0101
H
.
POINT
The reserved bits in Table 4.7 are for system use, not for users.
Therefore, always fix them to 0. If used (changed from 0 to 1) by a user, the
operations of the QD63P6 are not ensured.
(2) Details of the intelligent function module switch setting
Table 4.8 Details of the intelligent function module switch setting
Setting item
Description
Reference
Pulse input mode
Set the pulse input mode for each channel.
When setting 6
H
to F
H
, a switch setting error (error code:
810) occurs. (Refer to Section 8.5.)
Counting speed setting
Set the counting speed for each channel.
(When setting 11 (3
H
), a switch setting error (error code:
810) occurs. (Refer to Section 8.5.)
Counter format
Set the counter format for each channel.
Present value selection
setting
Set the same storage location of the present counter
value (present value A (Un\G10 and 11)/present value B
(Un\G200 and 201)) to all channels.