Reduces maintenance work drastically.
Enables you to check operation data of the indoor and outdoor units by remote controller.
Furthermore, use of maintenance stable-operation control that fix es the operating freq uency, allows smooth inspection, even for
inverter models.
1 3- 2 . M A I N T E N A N C E M O D E O P E R A T I O N M E T HO D
Note: If you are going to use 13-3. "GUIDE FOR OPERATION CONDITION", set the airflow to "High" before activating maintenance mode.
S witc h ing to maintenanc e mode
Maintenance mode can be activated either when the air conditioner is operated or stopped.
It cannot be activated during test run.
* Maintenance information can be viewed even if the air conditioner is stopped.
D
A
C
B
Operation mode
Compressor information Outdoor unit information Indoor unit information
Confirm
Activate/ cancel maintenance mode
n
Remote controller button information
(1) Press the
TEST
button for 3 seconds to switch to maintenance mode.
[Display
A
]
MAINTENANCE
If stable operation is unnecessary or if you want to check the data with the air conditioner stopped, skip to step (4).
F ix ed Hz op eration
The operating freq uency can be fixe d to stabilize operation of inverter model.
If the air conditioner is currently stopped, start it by this operation.
(2) Press the
MODE
button to select the desired operation mode.
[Display
A
]
(3) Press the
FILTER
( ) button to confirm the setting.
[Display
D
] Waiting for stabilization
HEAT
STAB LE MODE
STAB LE MODE
CANCEL
COOL
STAB LE MODE
Stable cooling
operation
Stable heating
operation
Stable operation
cancellation
Stabilized
After 10 to 20 minutes
D isc h arge temp erature 6 4
:
Remove the
service panel.
Measure
the intake air
temperature.
Measure the discharge
temperature.
Measure the outside air
temperature
l
Indoor unit
l
l
Outdoor unit
l
Smooth Mainte-
nance Function
l
Conventional inspection work
Easy maintenance information (unit)
Compressor
Outdoor unit
Indoor unit
Accumulated operating
Heat exch anger
7
Intake air
time (
o
10 hours)
temperature (
:
)
temperature (
:
)
Number of ON/ OFF
Discharge
8
4
5
1
2
9
6
3
Heat exch anger
times (
o
10 times)
temperature (
:
)
temperature (
:
)
Operating
Outside air
Filter operating
current (A)
temperature (
:
)
time* (Hours)
* The filter operating time is the time that has elapsed since the filter was reset.
1 3- 1 - 2 . P A R - 2 1 M A A
OCH526C
Содержание PUHZ-HW112YHA-BS