1. SPECIFICATIONS
OUTDOOR UNITS
10
Model
PUHY-RP700YSJM-B(-BS)
Power source
3-phase 4-wire 380-400-415V 50/60Hz
Cooling capacity
*1 kW
80.0
(Nominal)
*1 kcal / h
68,800
*1 BTU / h
273,000
Power input
kW
22.22
Current input
A
37.5-35.6-34.3
COP
kW / kW
3.60
Temp. range of
Indoor
W.B.
15.0~24.0°C(59~75°F)
cooling
Outdoor
D.B.
-5.0~43.0°C(23~109°F)
Heating capacity
*2 kW
88.0
(Nominal)
*2 kcal / h
75,700
*2 BTU / h
300,300
Power input
kW
20.13
Current input
A
33.9-32.2-31.1
COP
kW / kW
4.37
Temp. range of
Indoor
D.B.
15.0~27.0°C(59~81°F)
heating
Outdoor
W.B.
-20.0~15.5°C(-4~60°F)
Indoor unit
Total capacity
50~130 % of outdoor unit capacity
connectable
Model / Quantity
P15~P250 / 1~32
Sound pressure level (measured in anechoic room) dB <A>
61.5
Refrigerant
Liquid pipe
mm (in.)
19.05(3/4) Brazed
piping diameter
Gas pipe
mm (in.)
41.28(1-5/8) Brazed
Set Model
Model
PUHY-RP200YJM-B(-BS)
PUHY-RP250YJM-B(-BS)
PUHY-RP250YJM-B(-BS)
FAN
Type x Quantity
Propeller fan x 1
Propeller fan x 1
Propeller fan x 1
Air flow rate
m
3
/ min
185
185
185
L/s
3,083
3,083
3,083
cfm
6,532
6,532
6,532
Control , Driving mechanism
Inverter-control, Direct-driven by motor
Inverter-control, Direct-driven by motor
Inverter-control, Direct-driven by motor
Motor output
kW
0.92 x 1
0.92 x 1
0.92 x 1
*3 External static press.
0 Pa (0 mmH
2
O)
0 Pa (0 mmH
2
O)
0 Pa (0 mmH
2
O)
Compressor
Type x Quantity
Inverter scroll hermetic compressor
Inverter scroll hermetic compressor
Inverter scroll hermetic compressor
Manufacture
AC&R Works, MITSUBISHI ELECTRIC
CORPORATION
AC&R Works, MITSUBISHI ELECTRIC
CORPORATION
AC&R Works, MITSUBISHI ELECTRIC
CORPORATION
Starting method
Inverter
Inverter
Inverter
Motor output
kW
4.8
6.8
6.8
Case heater
kW
0.035(240 V)
0.045(240 V)
0.045(240 V)
Lubricant
MEL32
MEL32
MEL32
External finish
Pre-coated galvanized steel sheets
(+powder coating for -BS type)
Pre-coated galvanized steel sheets
(+powder coating for -BS type)
Pre-coated galvanized steel sheets
(+powder coating for -BS type)
<MUNSELL 5Y 8/1 or similar>
<MUNSELL 5Y 8/1 or similar>
<MUNSELL 5Y 8/1 or similar>
External dimension HxWxD
mm
1,710(1,650 without legs) x 920 x 760
1,710(1,650 without legs) x 920 x 760
1,710(1,650 without legs) x 920 x 760
in.
67-3/8(65 without legs) x 36-1/4 x 29-15/
16
67-3/8(65 without legs) x 36-1/4 x 29-15/
16
67-3/8(65 without legs) x 36-1/4 x 29-15/
16
Protection devices
High pressure protection
High pressure sensor, High pressure
switch at 4.15,3.3MPa (601,479 psi)
High pressure sensor, High pressure
switch at 4.15,3.3MPa (601,479 psi)
High pressure sensor, High pressure
switch at 4.15,3.3MPa (601,479 psi)
Inverter circuit (COMP. / FAN)
Over-heat protection, Over-current pro-
tection
Over-heat protection, Over-current pro-
tection
Over-heat protection, Over-current pro-
tection
Compressor
Over-heat protection
Over-heat protection
Over-heat protection
Fan motor
Thermal switch
Thermal switch
Thermal switch
Refrigerant
Type x original charge
R410A x 6.5kg (15lbs)
R410A x 9.0kg (20lbs)
R410A x 9.0kg (20lbs)
Control
LEV and HIC circuit
Net weight
kg (lbs)
230(508)
255(563)
255(563)
Heat exchanger
Salt-resistant cross fin & copper tube
Salt-resistant cross fin & copper tube
Salt-resistant cross fin & copper tube
HIC circuit (HIC: Heat Inter-Changer)
Copper pipe,tube-in-tube structure
Copper pipe,tube-in-tube structure
Copper pipe,tube-in-tube structure
Pipe between unit and
Liquid pipe
mm (in.)
9.52(3/8) Brazed
9.52(3/8) Brazed
9.52(3/8) Brazed
distributor
Gas pipe
mm (in.)
19.05(3/4) Brazed
22.2(7/8) Brazed
22.2(7/8) Brazed
Defrosting method
Auto-defrost mode (Reversed refrigerant cycle)
Drawing
External
KD94G727
Wiring
KE94C490
KE94C490
KE94C490
Standard attachment
Document
Installation Manual
Accessory
Refrigerant conn. pipe
Optional parts
Outdoor Twinning kit: CMY-RP200VBK
Header: CMY-Y104/108/1010-G
Remarks
●
.Details on foundation work, duct work, insulation work, electrical wiring, power source switch, and other items shall be re-
ferred to the Installation Manual.
●
.Due to continuing improvement, above specifications may be subject to change without notice.
●
.Our company is unable to guarantee reliability of pre-existing pipes and pre-existing cables.
Notes :
Unit converter
1.Nominal cooling conditions (subject to JIS B8615-1)
Indoor: 27°CDB/19°CWB (81°FDB/66°FWB), Outdoor: 35°CDB (95°FDB)
Pipe length: 7.5 m (24-9/16 ft.), Level difference: 0 m (0 ft.)
2.Nominal heating conditions (subject to JIS B8615-1)
Indoor: 20°CDB (68°FDB), Outdoor: 7°CDB/6°CWB (45°FDB/43°FWB)
Pipe length: 7.5 m (24-9/16 ft.), Level difference: 0 m (0 ft.)
3.External static pressure option is available (30 Pa, 60 Pa/3.1 mmH
2
O, 6.1 mmH
2
O).
kcal
=kW x 860
BTU/h =kW x 3,412
cfm
=m
3
/min x 35.31
lbs
=kg / 0.4536
*The specification data is
subject to rounding variation.