![Mitsubishi Electric PQHY-P-T(S)LMU-A Скачать руководство пользователя страница 23](http://html.mh-extra.com/html/mitsubishi-electric/pqhy-p-t-s-lmu-a/pqhy-p-t-s-lmu-a_installation-manual_1811130023.webp)
23
GB
7.1. Installation
[Fig. 7.1.1] (P.2)
A
M10 anchor bolt. (field-supplied)
B
Check that the installation leg
corners are securely supported to
ensure that the legs do not bend.
C
Check that the installation leg
corners are securely supported.
•
Attach unit tightly with bolts so that it will not fall down due to earthquakes or
strong winds.
•
Use concrete or an angle bracket for the foundation.
•
Vibration may be transmitted to the installation area and noise and vibration
may be generated from the floor and walls, depending on the conditions.
Provide ample vibration proofing (cushion pads, cushion frame, etc.).
• Be sure that the corners are firmly attached. If the corners are not firmly
attach, the feet of the unit may be bent.
•
When using pads, be sure that the full width of the unit is covered.
• The projecting length of the anchor bolt should be less than 25 mm [1 in.].
•
The PQHY/PQRY-P·TLMU-A/YLMU-A should not be installed at outdoor.
Warning:
•
Install the unit in a location strong enough to withstand its weight.
Any lack of strength may cause unit to fall down, resulting in a
personal injury.
•
Have installation work in order to protect against strong winds and
earthquakes.
Improper installation may cause unit to fall down, resulting in a
personal injury.
When building the foundation, give full attention to the floor strength, drain water
disposal <during operation, drain water flows out of the unit>, and piping and
wiring routes.
7.2. Service space
•
Allow for clearance space.
•
In case of a single unit installation, include 600 mm or more of space for
easier access when servicing the unit from back.
[Fig. 7.2.1] (P.2)
A
Space for removing the control box
B
Heat source unit
C
Service space (front)
7. Installation
[Fig. 6.0.1] (P.2)
A
Suspension Ropes (8m [26ft] or longer × 2 ropes)
B
Protective Pads (front and back, 4 points)
•
Use transporting ropes that can hold the weight of the unit.
•
When moving the unit, use a
4-point suspension
, and avoid giving impacts
to the unit (Do not use
2-point suspension
).
•
Place protective pads on the unit where it comes in contact with the ropes to
protect the unit from being scratched.
•
Set the angle of roping at 40° or less.
•
Use 2 ropes that are each longer than 8m [26ft].
Caution:
Be very careful when carrying/moving the product.
- When installing the heat source unit, suspend the unit at the specified location
of the unit base. Support the unit of the four points, and stabilize as necessary.
If the unit is suspended with 3-point support, the unit may fall.
6. Transporting the unit
5. Parts list
•
Check if the unit is shipped with the parts listed below.
•
For precautions, see section 10.2.
PQHY-P·TLMU-A/YLMU-A
Model
1
Connecting
elbow
IDø28.6,
ODø28.6
<Gas side>
2
Connecting
pipe
IDø15.88,
ODø15.88
<Liquid side>
3
Water
stopper
<Liquid side>
4
Water
stopper
<Gas side>
5
Sealing
material
for water
stopper
<Liquid side>
6
Sealing
material
for water
stopper
<Gas side>
7
Sealing
material
for field piping
<Liquid side>
8
Sealing
material
for field piping
<Gas side>
9
Sealing
material
for base leg
0
Sealing
material
for base leg
a
Sealing
material
for water panel
b
Pipe cover
<Gas side>
c
Sealing
material
for drain
socket
P72
1 pc.
1 pc.
1 pc.
1 pc.
1 pc.
1 pc.
1 pc.
1 pc.
–
–
–
1 pc.
1 pc.
P96
1 pc.
1 pc.
1 pc.
1 pc.
1 pc.
1 pc.
1 pc.
1 pc.
–
–
–
1 pc.
1 pc.
P120
1 pc.
1 pc.
1 pc.
1 pc.
1 pc.
1 pc.
1 pc.
1 pc.
–
–
–
1 pc.
1 pc.
P144
1 pc.
1 pc.
1 pc.
1 pc.
1 pc.
1 pc.
1 pc.
1 pc.
4 pc.
4 pc.
1 pc.
1 pc.
1 pc.
P168
1 pc.
1 pc.
1 pc.
1 pc.
1 pc.
1 pc.
1 pc.
1 pc.
4 pc.
4 pc.
1 pc.
1 pc.
1 pc.
P192
1 pc.
1 pc.
1 pc.
1 pc.
1 pc.
1 pc.
1 pc.
1 pc.
4 pc.
4 pc.
1 pc.
1 pc.
1 pc.
P216
1 pc.
1 pc.
1 pc.
1 pc.
1 pc.
1 pc.
1 pc.
1 pc.
4 pc.
4 pc.
1 pc.
1 pc.
1 pc.
P240
1 pc.
1 pc.
1 pc.
1 pc.
1 pc.
1 pc.
1 pc.
1 pc.
4 pc.
4 pc.
1 pc.
1 pc.
1 pc.
PQRY-P·TLMU-A/YLMU-A
Model
1
Connecting
elbow
IDø28.6,
ODø28.6
<Low-pressure
side>
2
Connecting
pipe
IDø15.88,
ODø15.88
<High-pressure
side>
3
Water
stopper
<High-pressure
side>
4
Water
stopper
<Low-pressure
side>
5
Sealing
material
for water
stopper
<High-pressure
side>
6
Sealing
material
for water
stopper
<Low-pressure
side>
7
Sealing
material
for field piping
<High-pressure
side>
8
Sealing
material
for field piping
<Low-pressure
side>
9
Sealing
material
for base leg
0
Sealing
material
for base leg
a
Sealing
material
for water panel
b
Pipe cover
<Low-pressure
side>
c
Sealing
material
for drain
socket
P72
1 pc.
–
–
1 pc.
–
1 pc.
1 pc.
1 pc.
–
–
–
1 pc.
1 pc.
P96
1 pc.
–
–
1 pc.
–
1 pc.
1 pc.
1 pc.
–
–
–
1 pc.
1 pc.
P120
1 pc.
–
–
1 pc.
–
1 pc.
1 pc.
1 pc.
–
–
–
1 pc.
1 pc.
P144
1 pc.
–
–
1 pc.
–
1 pc.
1 pc.
1 pc.
4 pc.
4 pc.
1 pc.
1 pc.
1 pc.
P168
1 pc.
–
–
1 pc.
–
1 pc.
1 pc.
1 pc.
4 pc.
4 pc.
1 pc.
1 pc.
1 pc.
P192
1 pc.
–
–
1 pc.
–
1 pc.
1 pc.
1 pc.
4 pc.
4 pc.
1 pc.
1 pc.
1 pc.
P216
1 pc.
–
–
1 pc.
–
1 pc.
1 pc.
1 pc.
4 pc.
4 pc.
1 pc.
1 pc.
1 pc.
P240
1 pc.
–
–
1 pc.
–
1 pc.
1 pc.
1 pc.
4 pc.
4 pc.
1 pc.
1 pc.
1 pc.