3. Installing the indoor unit
3.2. Ceiling openings and suspension bolt installation
locations (Fig. 3-2)
Warning:
• This unit should be installed in rooms which exceed the floor space specified
in outdoor unit installation manual.
Refer to outdoor unit installation manual.
• Install the indoor unit at least 2.5 m above floor or grade level.
For appliances not accessible to the general public.
• Refrigerant pipes connection shall be accessible for maintenance purposes.
• Using the installation template (top of the package) and the gauge (supplied as an
accessory with the grille), make an opening in the ceiling so that the main unit can
be installed as shown in the diagram. (The method for using the template and the
gauge is shown.)
* Before using, check the dimensions of template and gauge, because they
change due to fluctuations of temperature and humidity.
* The dimensions of ceiling opening can be regulated within the range shown in
Fig. 3-2; so center the main unit against the opening of ceiling, ensuring that the
respective opposite sides on all sides of the clearance between them becomes
identical.
• Use M10 (3/8") suspension bolts.
* Suspension bolts are to be procured at the field.
• Install securely, ensuring that there is no clearance between the ceiling panel &
grille, and between the main unit & grille.
A
Outer side of main unit
E
Grille
B
Bolt pitch
F
Ceiling
C
Ceiling opening
G
Multi functional casement (option)
D
Outer side of Grille
H
Entire periphery
* Note that the space between ceiling panel of the unit and ceiling slab, etc. must be
7 mm or more.
*
When the optional multi-functional casement is installed, add 135 mm to the
dimensions marked on the figure.
(mm)
Models
A
B
ZM35-60
241
258
ZM71-140
281
298
3.3. Refrigerant and drainage piping locations of indoor
unit (Fig. 3-3)
The figure marked with * in the drawing represent the dimensions of the main unit
excluding those of the optional multi function casement.
A
Drain pipe
B
Ceiling
C
Grille
D
Refrigerant pipe (liquid)
E
Refrigerant pipe (gas)
F
Main unit
* When the optional multi-functional casement is installed, add 135 mm to the
dimensions marked on the figure.
(mm)
Models
C
D
ZM35, 50
76
76.5
ZM60-140
79.5 79.5
Fig. 3-3
Fig. 3-2
145
795
B
860 – 910
C
950
D
20 – 45
20 – 45
145
660
B
(20)
(20)
840
A
950
D
20 – 45
860 – 910
C
20 – 45
193
222
133
145
145
F
E
G
135
17
+5 0
*50
– 70
* B
A
F
E
17
40
+5 0
*105
H
*140
*170
*190
6
D
C
60
357
271
D
E
F
B
A
C
79.5
79.5
Min. 1500
Floor
Min. 2500