20
Model name
Indoor unit
PCA-RP71HA
PCA-RP125HA
PCA-RP125HA
Outdoor unit
PUHZ-RP71VHA4
PUHZ-RP125VKA
PUHZ-RP125YKA
Cooling
Capacity
Btu/h
24,200
42,700
42,700
kW
7.1(3.3-8.1)
12.5(5.5-14.0)
12.5(5.5-14.0)
Total input
kW
2.21
3.88
3.88
EER
3.21
3.22
3.22
Energy label class
A
A
A
SHF
0.74
0.77
0.77
Heating
Capacity
Btu/h
25,900
47,100
47,100
kW
7.6(3.5-10.2)
13.8(5.0-16.0)
13.8(5.0-16.0)
Total input
kW
2.23
4.05
4.05
COP
3.41
3.41
3.41
Energy label class
B
B
B
Booster heater
kW
-
-
-
Power supply
Phase
:
1
3
Cycle
Hz
50
50
Voltage
V
230
400
Breaker size
A
25
16
Indoor unit
Air flow
CMM
17-19
30-38
(Low-High)
CFM
600-670
1,060-1,350
External pressure
Pa
0
Sound level
dB(A)
34-38
44-50
(Low-High)
External finish
Stainless steel
Dimension
W : mm
1136
1520
D : mm
650
H : mm
280
W : inch
44-3/4
59-7/8
D : inch
25-5/8
H : inch
11
Weight
kg
41
56
lbs
90
124
Field drain pipe O.D.
mm
26
inch
1
Outdoor unit
Air flow
CMM
60
120
CFM
2,120
4,230
Sound level at cooling
dB(A)
47
50
Sound level at heating
dB(A)
48
52
External finish
Ivory Munsell 3Y 7.8/1.1
Dimension
W : mm
950
1,050
D : mm
330+30
330+30
H : mm
943
1,338
W : inch
37-3/8
41-5/16
D : inch
13 + 1-3/16
13 + 1-3/16
H : inch
37-1/8
52-11/16
Weight
kg
67
116
126
lbs
148
256
278
Refrigerant pipe size
Gas side O.D.
mm
15.88
15.88
inch
5/8
5/8
Liquid side O.D.
mm
9.52
9.52
inch
3/8
3/8
Refrigerant pipe length
Height difference
m
Max. 30
Max. 30
Length
m
Max. 50
Max. 75
NOTE:
1. Rating conditions (ISO T1)
Cooling Indoor : D.B. 27
(80°F) W.B. 19
(66°F)
Outdoor : D.B. 35
(95°F) W.B. 24
(75°F)
Heating Indoor : D.B. 20
(68°F)
Outdoor : D.B. 7
(45°F)
W.B. 6
(43°F)
Refrigerant piping length (one way) : 5m (16ft.)
2. Guaranteed operating range
Indoor
Outdoor
Cooling
Upper limit D.B. 35°C, W.B. 22.5°C D.B. 46°C
Lower limit D.B. 19°C, W.B. 15°C
D.B. -5°C
+
Heating
Upper limit D.B. 28°C
D.B. 21°C, W.B. 15°C
Lower limit D.B. 17°C
D.B. -20°C, W.B. -20°C
4. Above data are based on the indicated voltage.
+
If optional air protect guide installed. D.B.-15
Indoor unit
Single phase 230V 50Hz
V: Single phase 230V 50Hz,
Y: 3 phase 400V 50Hz
Outdoor unit
3. Guaranteed voltage
198~264V, 50Hz (RP125Y : 342~457V, 50Hz)