![Mitsubishi Electric PKA-RP HAL Скачать руководство пользователя страница 8](http://html.mh-extra.com/html/mitsubishi-electric/pka-rp-hal/pka-rp-hal_technical-data-book_238265008.webp)
8
Model name
Indoor unit
PLA-RP125BA
PLA-RP125BA2
PLA-RP140BA2
Outdoor unit
PUHZ-RP125YKA
PUHZ-RP125YKA
PUHZ-RP140YKA
Cooling
Capacity
Btu/h
kW
Total input
kW
EER
Energy label class
SHF
Heating
Capacity
Btu/h
kW
Total input
kW
COP
Energy label class
Booster heater
kW
Power supply
Phase
:
3
Cycle
Hz
50
Voltage
V
400
Breaker size
A
16
Indoor unit
Air flow
CMM
(Low-Medium2-Medium1-High)
CFM
External pressure
Pa
Sound level
dB(A)
(Low-Medium2-Medium1-High)
External finish (Panel)
Dimension
W : mm
Unit (Panel)
D : mm
H : mm
W : inch
D : inch
H : inch
Weight
kg
Unit (Panel)
lbs
Field drain pipe O.D.
mm
inch
Outdoor unit
Air flow
CMM
CFM
Sound level at cooling
dB(A)
Sound level at heating
dB(A)
External finish
Dimension
W : mm
D : mm
H : mm
W : inch
D : inch
H : inch
Weight
kg
126
132
lbs
278
291
Refrigerant pipe size
Gas side O.D.
mm
15.88
inch
5/8
Liquid side O.D.
mm
9.52
inch
3/8
Refrigerant pipe length
Height difference
m
Max. 30
Length
m
Max. 75
42,700
42,700
47,800
12.5(5.5-14.0)
12.5(5.5-14.0)
14.0(6.2-15.3)
3.83
3.67
4.36
3.26
3.41
3.21
–
A
A
0.71
0.71
0.71
47,800
47,800
54,600
14.0(5.0-16.0)
14.0(5.0-16.0)
16.0(5.7-18.0)
3.86
3.50
4.32
3.63
4.00
3.70
–
A
A
–
–
–
25(6)
55(13)
27(6)
60(13)
22-25-28-31
22-25-28-31
780-880-990-1090
780-880-990-1090
0
0
34-36-39-41
34-36-39-41
24-26-29-32
850-920-1020-1130
0
36-39-42-44
White Munsell 6.4Y 8.9/0.4
840 (950)
840 (950)
298 (35)
33-1/16 (37-3/8)
33-1/16 (37-3/8)
11-3/4 (1-3/8)
27(6)
60(13)
32
1-1/4
120
4,230
50
52
Ivory Munsell 3Y 7.8/1.1
1,050
330+30
1,338
41-5/16
13 + 1-3/16
52-11/16
NOTE:
1. Rating conditions (ISO T1)
Cooling Indoor : D.B. 27
(80°F) W.B. 19
(66°F)
Outdoor : D.B. 35
(95°F) W.B. 24
(75°F)
Heating Indoor : D.B. 20
(68°F)
Outdoor : D.B. 7
(45°F)
W.B. 6
(43°F)
Refrigerant piping length (one way) : 5m (16ft.)
2. Guaranteed operating range
Indoor
Outdoor
Cooling
Upper limit D.B. 35°C, W.B. 22.5°C D.B. 46°C
Lower limit D.B. 19°C, W.B. 15°C
D.B. -5°C
+
Heating
Upper limit D.B. 28°C
D.B. 21°C, W.B. 15°C
Lower limit D.B. 17°C
D.B. -20°C, W.B. -20°C
4. Above data are based on the indicated voltage.
Indoor unit
Single phase 230V 50Hz
3 phase 400V 50Hz
Outdoor unit
Indoor unit
198~264V, 50Hz
342~457V, 50Hz
Outdoor unit
3. Guaranteed voltage
If optional air protect guide installed. D.B.-15