39
CN51
X
5
4
3
Y
L
1
: Error display lamp
L
2
: Compressor operation lamp
X, Y : Relay (Coil standard of 0.9W or less for DC 12V)
CN3S
X
Y
SW1
SW2
1
2
3
X, Y : Relay (DC1mA)
SW1
SW2
ON
Heating
Validity of SW1
OFF
Cooling
Invalidity of SW1
Distant control board
Relay circuit
External output adapter (PAC-SA88HA-E)
Outdoor unit control board
Remote control panel
Relay circuit
External input adapter (PAC-SC36NA)
Outdoor unit control board
Relay power supply
Procure locally
Max. 10m
+
The indoor unit, which is operating in the mode different from
the one determined by external signal (CN3S), will be a state of standby.
+
The setting becomes effective when the outdoor unit is under stop.
+
The operation mode specified by test run will be prior to the mode of this function.
Lamp power supply
Procure locally
Max. 10m
~
~
Y
X
Y
X
L
1
L
2
Y
CNDM
SW2
1
2
3
Remote control panel
Relay circuit
External input adapter (PAC-SC36NA)
Outdoor unit control board
Replay power supply
Procure locally
Max. 10m
Orange
Brown
Red
~
Y
SW7-1
Power consumption when SW2 is on
OFF
0% (Forced compressor stop)
ON
50%
Fig. 9-1
9-5. SPECIAL FUNCTIONS
9-5-1. Low noise mode (on-site modification) (Fig. 9-1)
By performing the following modification, operation noise of the outdoor unit can be reduced by about 3-4 dB.
The low noise mode will be activated when a commercially available timer or the contact input of an ON/OFF switch is added
to the CNDM connector (optional parts) on the control board of the outdoor unit.
• The capacity may be insufficient according to the outdoor temperature and conditions, etc.
1
Complete the circuit as shown when using the external input adapter (PAC-SC36NA). (Optional parts)
SW1
X
CNDM
X
1
2
3
Remote control panel
Relay circuit
External input adapter (PAC-SC36NA)
Outdoor unit control board
Replay power supply
Procure locally
Max. 10m
Orange
Brown
Red
~
Fig. 9-2
9-5-2. Demand function (on-site modification) (Fig. 9-2)
• It is possible to reduce electricity consumption within a range from 0 to 100 % by performing the following on-site installation.
The demand function can be enabled by adding a commercially available input contact point ON/OFF switch to the CNDM
connector (the contact point demand input, optional parts).
1
Incorporate the “Adapter for external input (PAC-SC36NA)” into the circuit as shown in the diagram below.
2
By switching SW7-1 on the control circuit board for the outdoor unit, the following power consumption restrictions
(compared to rated power) can be set.
9-5-3. Error and compressor operation monitoring function (CN51)
Fig. 9-3
9-5-4. Auto change over - Operation mode locking function by external signal (CN3S)
Fig. 9-4
Содержание PAC-AK31BC
Страница 90: ...90 15 2 FUNCTIONAL PARTS BRANCH BOX PAC AK50BC 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 18 17 16 19 20 ...
Страница 92: ...92 15 3 FUNCTIONAL PARTS BRANCH BOX PAC AK30BC 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 18 17 16 ...
Страница 98: ...98 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 18 17 16 19 20 16 3 FUNCTIONAL PARTS BRANCH BOX PAC AK50BC PAC AK51BC ...
Страница 100: ...100 16 4 FUNCTIONAL PARTS BRANCH BOX PAC AK30BC PAC AK31BC 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 18 17 16 ...
Страница 160: ...Related Links Model Number MXZ8A140VA 3 MXZ 8A_Parts_Catalog_ OC316E MXZ 8A_Service_Manual_ OC316E ...