22
MXZ-8A140VA
1
MXZ-8A140VA
2
1
C. B.
MF1
4
5
6
7
CNF1 (WHT)
CN2 (WHT)
CN4 (WHT)
CN3S
(WHT)
CNDM
(WHT)
CN51
(WHT)
CNAC (WHT)
TH7/6 (RED)
TH3 (WHT)
1
21
2
TH4 (WHT)
1
2
3
4
63HS (WHT)
12
3
63H (YL
W)
31
63L
(RED)
31
CNIT (RED)
12
35
4
TH7
TH6
TH3
TH4
63HS
63H
63L
1
MF2
4
5
67
CNF2 (WHT)
CNDC (PNK)
CNS (WHT)
31
32
1
52C (BLK)
31
21S4 (GRN)
3
1
SV2 (BLU)
3
1
SV1 (GR
Y
)
31
SS
(WHT)
3
1
FUSE2
FUSE1
FUSE3
FUSE4
21S4
SV2
SV1
12 3
4
7
65
4
321
54
32
1
32
1
32
1
2
1
CNAF (WHT)
CNDC (PNK)
CN2 (WHT)
CN5 (RED)
7
654
32
1
21
CN3 (WHT)
2
1
CN4 (WHT)
2
1
6
543
21
13
TH8
IPM
LED1
WHT
BLK
B
LK
ACTM
RS
RED
WHT
WHT
BLK
RED
RED
TABP1
TABP2
TABN1
TABN2
TABN
TABP
TABS
TABT
BLU
WHT
DCL
TB1
NO FUSE BREAKER 40 A
BRANCH BOX
POWER SUPPL
Y
~/N 220/230/240V 50Hz 220V 60Hz
CE
L
N
S1
S2
S3
52C
N. F
.
P.
B
.
MC
CNAC2 (RED)
31
CNAC1 (WHT)
31
LI
NI
L0
N0
CN5 (RED)
2
1
EI
W
V
U
P
N1
N2
I
654
3
2
1
L1
L2
SW5
SW6
SW1
CN31
SW7
SW2
SW8
SW4
SW9
SW10
7SEG LED
88
SYMBOL
SYMBOL
SYMBOL
NAME
NAME
NAME
TB1
MC
MF1, MF2
21S4
SV1
SV2
63HS
63L
TH3
TH4
TH6
TH7
TH8
DCL
52C
RS
ACTM
CE
P.
B
63H
Te
rminal Block (Power Supply
, Branch)
Motor for Compressor
Fan Motors
Solenoid V
alve (Four-W
ay V
alve)
Solenoid V
alve (Hot Gas Bypass)
Solenoid V
alve (Returning oil Bypass)
High pressure Sensor
High pressure Switch
Low pressure Switch
Thermistor (Outdoor Pipe)
Thermistor (Discharge)
Thermistor (Outdoor2 - Phase Pipe)
Thermistor (Outdoor)
Thermistor (Heatsink)
Reactor
52C Relay
Rush Current Protect Resistor
Active Filter Module
Main Smoothing Capacitor
Power Circuit Board
TA
B - S /
T
TA
B-P/P1/P2
TA
B-N/N1/N2
CN2 ~ 5
CNDC
CNAF
IPM
LED1
LI / LO
NI / NO
EI
CNAC1 / 2
CN5
FUSE1 ~ 4
SW1
SW2
SW4
Te
rminal (L
/ N - Phase)
Te
rminal (DC V
oltage)
Te
rminal (DC V
oltage)
Connector
Connector
Connector
Inverter
Light Emitting Diodes (Inverter Control Status)
Noise Filter Circuit Board
Connection Lead (L
- Phase)
Connection Lead (N - Phase)
Connection T
erminal
(Ground)
Connector
Connector
Controller Circuit Board
Fuse (6.3A)
Switch (Forced Defrost, Error History Record Reset)
Switch (Self Diagnosis Switch)
Switch (T
est Operation )
Connection
Te
rminal (U / V / W - Phase)
U / V / W
SW5
Switch (Function Switch)
SW6
SW7
SW8
SW9
SW10
CN31
LED
CNAC
CNDC
CNS
CNF1
CNF2
SS
SV1
SV2
CN3S
CNDM
CN51
CNIT
Switch (Model Select)
Switch (Function Setup)
Switch
Switch (Function for option)
Switch (Function for option)
Connector
Light Emitting Diodes (Operation Inspection Indicators)
Connector
Connector
Connector
Connector
Connector
Connector (Connection for Option)
Connector
Connector
Connector (Connection for Option)
Connector <Connected for Option (Contact Input)>
Connector (Connection for Option)
Connector (Connection for Option)
N. F
.
C. B.
Power turned on
Details
W
A
RNING: When the main supply is turned of
f, the voltage[340 V]in the main capacitor will drop to 20 V in approx.2 minut
es
(input voltage : 240 V). When servicing, make sure that LED on the outdoor circuit board gose out, and then wait for at
least 1 minute.
Components other than the outdoor board may be faulty : Check and take corrective action, referring to the service manual.
Do not replace the outdoor board without checking.
Cautions when Servicing
LED on the controller board display the operation and inspection status as follows.
If LED does not light, it indicates that no power is supplied to the board:
Operation / Inspection Display
Normal status
Faulty status (blinking)
Code
(blinks)
Operation status display
,
such as C5. H7
F3
F5
F9
E8
E9
EA
Eb
Ec
E0 E7
EE, EF
Ed
U2
U7
U1
UL
U6
UF
UH
UP
U3
U4
U5
U8
U9
PA
63L
connector (red) is open.
63H connector (yellow) is open.
2 connectors (63H/63L) are open.
Branch box/outdoor communication error (Signal receiving error) (Outdoor unit)
Indoor/branch box communication error (Signal receiving error) (Branch box)
Branch box/outdoor communication error (T
ransmitting error) (Outdoor unit)
Indoor/branch box communication error (T
ransmitting error) (Branch box)
Miswiring of indoor-branch box / branch box-outdoor unit connecting wire.
Too many indoor units / branch box are in the system.
Miswiring of indoor-branch box/branch box-outdoor unit connecting wire (converse wiring or disconnection)
Startup time over
Communication error except for outdoor unit
Combination error
, undefined error
Serial communication error
Discharge temperature fault
Low-discharge superheating fault, Erroneous connection of refrigerant pipes or
the connecting wires
High pressure fault (63H operates)
Low pressure fault (63L
operates)
Abnormality of power modules
Compressor overcurrent shutof
f (Start up locked)
Current sensor fault (P
. B.)
Compressor overcurrent shutof
f fault
Discharge pipe/compressor thermistor (TH4) open or short-circuit
Outdoor unit thermistors (TH3,
TH6,
TH7, and
TH8), 63HS, and branch box
thermistors open or short-circuit
Heatsink temperature fault
Abnormality in outdoor fan motor
V
oltage fault, current sensor fault (N. F
.)
Forced compressor stop
(Overlap malfunction of drain pump in indoor unit
and linear expansion valve in branch box)
Содержание PAC-AK31BC
Страница 90: ...90 15 2 FUNCTIONAL PARTS BRANCH BOX PAC AK50BC 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 18 17 16 19 20 ...
Страница 92: ...92 15 3 FUNCTIONAL PARTS BRANCH BOX PAC AK30BC 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 18 17 16 ...
Страница 98: ...98 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 18 17 16 19 20 16 3 FUNCTIONAL PARTS BRANCH BOX PAC AK50BC PAC AK51BC ...
Страница 100: ...100 16 4 FUNCTIONAL PARTS BRANCH BOX PAC AK30BC PAC AK31BC 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 18 17 16 ...
Страница 160: ...Related Links Model Number MXZ8A140VA 3 MXZ 8A_Parts_Catalog_ OC316E MXZ 8A_Service_Manual_ OC316E ...