12
ADDITIONAL REFRIGERANT CHARGE (R410A:g)
Outdoor unit
precharged
750
850
14m
7m
6m
5m
11m
Model
Refrigerant piping length (one way)
8m
9m
10m
12m
13m
15m
20m
270
0
0
0
180
90
120
150
210
240
300
450
MUZ-GC25VA
MUZ-GC25VAH
MUZ-GC35VA
MUZ-GC35VAH
Max. length
A
Max. Height
difference
B
Indoor
unit
Outdoor unit
MAX. REFRIGERANT PIPING LENGTH and MAX. HEIGHT DIFFERENCE
Max. length
A
20
Max. Height difference
B
12
Model
Gas
9.52
Liquid
6.35
Piping size O.D : mm
Refrigerant piping : m
MUZ-GC25VA
MUZ-GC25VAH
MUZ-GC35VA
MUZ-GC35VAH
Calculation : Xg=30 g/m
✕
(Refrigerant piping length (m)–5)
NOTE: Refrigerant piping exceeding 7 m requires additional refrigerant charge according to the calculation.