9
Unit: mm
MUZ-EF25VE MUZ-EF25VEH MUZ-EF35VE MUZ-EF35VEH MUZ-EF42VE
10
69
800
302.5
500 Bolt pitch for installation
150
22.3
Handle
550
280
164.5
99.5
170.5
23
Service panel
Service port
285
344.5
44
400
Air in
Air out
Air in
17.5
Bolt pitch for
installation
304~325
40
Liquid refrigerant pipe joint
Refrigerant pipe (flared) ø6.35
Gas refrigerant pipe joint
Refrigerant pipe (flared) ø9.52
43
35
2 holes 10 X 21
Drain hole ø42
(MUZ-EF25/35/42VE)
Drain hole ø33
(MUZ-EF25/35VEH)
REQUIRED SPACE
350 mm or more
100 mm or more
100 mm or more
*1 100 mm or more when front
and sides of the unit are clear
*2 When any 2 sides of left, right
and rear of the unit are clear
Clear *1
200 mm or
more *2
MUZ-EF50VE
OUTLINES AND DIMENSIONS
5
417.5
40
42
Drain hole
175
500
330
50
Air in
Air out
2-holes 10 21
360
840
109
81
880
452
Service panel
99.5
164.5
195
35
44
Liquid refrigerant pipe joint
Refrigerant pipe (flared)
Ø
6.35
Gas refrigerant pipe joint
Refrigerant pipe (flared)
Ø
12.7
350 mm or more
100 mm or more
REQUIRED SPACE
100 mm or more
500 mm
or more *2
*1 500 mm or more when front
and sides of the unit are clear
*2 When any 2 sides of left, right
and rear of the unit are clear
Clear *1
OBH590G
Содержание MUZ-EF25VE
Страница 11: ...11 MUZ EF25VE E5 ER5 ET5 MUZ EF35VE E5 ER5 ET5 MUZ EF25VEH E1 MUZ EF35VEH E1 OBH590G ...
Страница 12: ...12 MUZ EF25VEH E4 MUZ EF35VEH E4 MUZ EF25VEH E2 E3 ER2 ER3 ET2 ET3 MUZ EF35VEH E2 E3 ER2 ER3 ET2 ET3 OBH590G ...
Страница 13: ...13 MUZ EF42VE E1 MUZ EF50VE E1 MUZ EF42VE E2 E3 E4 ER3 ER4 ET3 ET4 MUZ EF50VE E2 ER2 ET2 OBH590G ...
Страница 14: ...14 MUZ EF42VE E5 ER5 ET5 MUZ EF50VE E3 ER3 ET3 OBH590G ...
Страница 57: ...57 OBH590G ...