![Mitsubishi Electric MUY-GL09NA Скачать руководство пользователя страница 43](http://html.mh-extra.com/html/mitsubishi-electric/muy-gl09na/muy-gl09na_service-manual_1810875043.webp)
43
)ORZFKDUWRIWKHGHWDLOHGRXWGRRUXQLWIDLOXUHPRGHUHFDOOIXQFWLRQ
2.Blinking pattern when outdoor unit is abnormal:
ON
OFF
No beep
Beeps
Repeated cycle
2.5-second OFF
3-second ON
Blinking at 0.5-
second interval
No beep
Beeps
Repeated cycle
2.5-second OFF
3-second ON
Blinking at 0.5-
second interval
Repeated cycle
Does the upper lamp of the OPERATION INDICATOR
lamp on the indoor unit blink at the interval of 0.5 seconds?
Blinks: The outdoor unit is abnormal. Beep is emitted at
the same timing as the blinking of the upper lamp
of the OPERATION INDICATOR lamp.
2
Yes
(Blinks
)
No
(OFF)
The outdoor unit might be abnormal.
Check if outdoor unit is abnormal according to the following procedures.
Operational procedure
Make sure that the remote controller is set to the failure mode recall function.
With the remote controller headed towards the indoor unit, press TOO
COOL button to adjust the set temperature to 77°F (25°C). 1
1. Regardless of normal or abnormal condition, 2 short
beeps are emitted as the signal is received.
The outdoor unit is abnormal.
Check the blinking pattern, and identify the abnormal point by referring to
the outdoor unit failure recall mode table (10-2.3.).
Make sure to check at least 2 consecutive blinking cycles. 2
Releasing the failure mode recall function
Release the failure mode recall function by the following procedures.
Turn OFF the power supply and turn it ON again.
Press RESET button of the remote controller.
Repair the failure parts.
The outdoor unit is normal.
Release the failure mode recall function accord-
ing to the left mentioned procedure.
Deleting the memorized abnormal condition
After repairing the unit, recall the failure mode again according to "Setting up the failure mode recall
function" (10-2.1.).
Press STOP/OPERATE (OFF/ON) button of the remote controller (the set temperature is displayed) with
the remote controller headed towards the indoor unit.
Press EMERGENCY OPERATION switch so that the memorized abnormal condition is deleted.
Release the failure mode recall function according to "Releasing the failure mode recall function" men-
tioned above.
NOTE
: 1. Make sure to release the failure mode recall function after it is set up, otherwise the unit cannot operate properly.
2. If the abnormal condition is not deleted from the memory, the last abnormal condition is kept memorized.
OBH733G
Содержание MUY-GL09NA
Страница 9: ...9 5 WIRING DIAGRAM MUZ GL09NA U1 U8 MUZ GL12NA U1 MUZ GL09NA U2 MUZ GL12NA U2 OBH733G ...
Страница 10: ...10 MUZ GL09NAH U2 MUZ GL12NAH U2 MUZ GL09NAH U1 U8 MUZ GL12NAH U1 OBH733G ...
Страница 11: ...11 MUY GL09NA U1 MUY GL12NA U1 MUY GL09NA U2 MUY GL12NA U2 OBH733G ...
Страница 12: ...12 MUZ GL15NA U2 MUZ GL15NA U1 OBH733G ...
Страница 13: ...13 MUZ GL15NAH U2 MUZ GL15NAH U1 OBH733G ...
Страница 14: ...14 MUY GL15NA U1 MUY GL15NA U2 OBH733G ...
Страница 15: ...15 MUZ GL18NA OBH733G ...
Страница 16: ...16 MUZ GL18NAH OBH733G ...
Страница 17: ...17 MUY GL18NA OBH733G ...
Страница 18: ...18 MUZ GL24NA OBH733G ...
Страница 19: ...19 MUZ GL24NAH OBH733G ...
Страница 20: ...20 MUY GL24NA OBH733G ...
Страница 75: ...75 OBH733G ...